MASTER CODE COMMANDS
SET THE TECHNICIAN CODE (PUBLIC USE FUNCTION ONLY)
#Master Code
10
Technician Code
Technician Code
••
Example: #11223344
10
555555
555555
••
Result: Technician Code 555555 now valid.
Note:
The Technician Code will open lock without erasing the Public Use Code.
Opening the lock with the Master Code or Sub-Master Code will erase the
Public Use Code.
DELETE THE TECHNICIAN CODE (PUBLIC USE FUNCTION ONLY)
#Master Code
11
11
••
Example: 11223344
11
11
••
Result: Technician Code deleted.
SET DUAL CODE MODE (PRIVATE USE FUNCTION ONLY)
#Master Code
12
12
••
Example: #11223344
12
12
••
Result: TWO valid codes required to open the lock or the Master Code only.
They can be any combination of the following codes:
User Code + User Code
User Code + Sub-Master Code.
CANCEL DUAL CODE MODE (PRIVATE USE FUNCTION ONLY)
#Master Code
13
13
••
Example: #11223344
13
13
••
Result: Lock will revert to only requiring one single code to open the lock.
Note: When switching between Program 12 and 13, codes and selected
programs are retained.
Programming
& Operating
Instructions
POI-KL1500-v3:0613
KL15OO
MASTER CODE COMMANDS
RESTRICT THE LOCKED TIME (PUBLIC USE FUNCTION ONLY)
#Master Code
14
(number of hours lock to remain locked)
••
Example 1: #11223344
14
04
••
Result:
After 4 hours from the time it was locked, the Public Use Code will be
erased. A Master or Sub-Master Code now required to open the lock.
Once opened with the Master or Sub-Master Code the lock will then revert to
B) Public Use with the lock open waiting for a new single Public Use Code
to be entered.
If the lock is opened during the set 4 hour period with a User or Master
Code then the lock will remain unlocked. At this point the restricted lock
time expires until a New User Code is entered.
Note:
Program 16 (Auto-Open Time) will have priority if programmed.
The available restricted locked time periods in hours are:
00, 02, 04, 06, 08, 10 or 12.
To end restricted locked time use following program:
#Master Code
14
00
••
Example: #11223344
14
00
••
Result: Locked time will not be restricted i.e. will remain locked until User,
Master or Sub-Master Code entered or Auto-Open Time, Program 16 is
activated.
SET 24 HOUR CLOCK TO RUN (PUBLIC USE FUNCTION ONLY)
#Master Code
15
07
30
••
Example: #11223344
15
07
30
••
Result: Lock internal timer has been set to 07.30hrs and will start to run.
Note: Time must be reset for daylight saving when required.
MASTER CODE COMMANDS
SET AUTO OPEN TIME (PUBLIC USE FUNCTION ONLY)
#Master Code
16
hour
min
••
Example: #11223344
16
19
15
••
Result: Lock will auto-open every day at 19.15 hrs and remain unlocked until a
new code is entered.
Note: 24 hr clock must be set before program will operate.
CANCEL AUTO OPEN TIME (PUBLIC USE FUNCTION ONLY)
#Master Code
17
17
••
Example: #11223344
17
17
••
Result: Auto-Open Time is cancelled.
DISABLE/ENABLE SOUNDER
The default is for the sounder to activate at every button press. To disable the
sounder enter the following command:
#Master Code
18
18
••
Example: #11223344
18
18
••
Result: No sound when buttons pressed.
To enable the sounder, repeat above code sequence.
RED LED LOCKED STATUS (PUBLIC USE FUNCTION ONLY)
Note: The factory default is for the Red LED to flash when locked every
3 seconds in B) Public Use.
#Master Code
19
19
••
Example: #11223344
19
19
••
Result: When locked in B) Public Use – No Red LED flashing.
To enable the Red LED to flash in B) Public Use, repeat above code sequence.
SUB-MASTER CODE COMMANDS
SET OR CHANGE THE USER CODE (PRIVATE USE FUNCTION ONLY)
#Sub-Master Code
03
User Code ID
User Code
••
Example: #55667788
03
03
1355
••
Result: New User Code 1355 now valid in position 03.
SUSPEND INDIVIDUAL USER CODE (PRIVATE USE FUNCTION ONLY)
#Sub-Master Code
04
User Code ID
••
Example: #55667788
04
01
••
Result: User Code ID number 01 valid but suspended. This will be identified by
the Red and Blue LED signalling together after the code has been entered.
Lock will remain locked.
RESTORE INDIVIDUAL USER CODE (PRIVATE USE FUNCTION ONLY)
#Sub-Master Code
05
User Code ID
••
Example: #55667788
05
01
••
Result: User Code ID number 01 restored.
SUSPEND ALL USER CODES (PRIVATE USE FUNCTION ONLY)
#Sub-Master Code
06
••
Example: #55667788
06
••
Result: All User Codes suspended. Red and Blue LED will signal together after
every valid code is entered and lock will remain locked.
RESTORE ALL USER CODES (PRIVATE USE FUNCTION ONLY)
#Sub-Master Code
07
••
Example: #55667788
07
••
Result: All User Codes restored.
SET OR CHANGE THE SUB-MASTER CODE
#Sub-Master Code
08
Sub-Master Code
Sub-Master Code
••
Example: #55667788
08
22446688
22446688
••
Result: Sub-Master Code 22446688 now valid.
SUB-MASTER CODE COMMANDS
USER CODES
TECHNICIAN CODES
DISABLE/ENABLE SOUNDER
The default is for the sounder to activate at every button press. To disable the
sounder enter the following command:
#Sub-Master Code
18
18
••
Example: #55667788
18
18
••
Result: No sound when buttons pressed.
To enable the sounder, repeat above code sequence.
RED LED LOCKED STATUS (PUBLIC USE FUNCTION ONLY)
Note: The factory default is for the Red LED to flash when locked every
3 seconds in B) Public Use.
#Sub-Master Code
19
19
••
Example: #55667788
19
19
••
Result: When locked in B) Public Use – No Red LED flashing.
To enable the Red LED to flash in B) Public Use, repeat above code sequence.
USER CODE COMMANDS
A User Code can change a User Code:
#User Code
New User Code
••
Example: #1234
0000
••
Result: User Code has been changed from 1234 to 0000.
TECHNICIAN CODE COMMANDS
A Technician Code can open the lock when in B)
Public Use WITHOUT
deleting the User Code sequence:
Enter 6 digit Technician Code
lock opens for 3 seconds and then relocks.