Technical information

10/29/2014
Page 63 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
2CD
“On QuickConnect
Code” behavior
0
This setting defines special behavior that will occur when a
QuickConnect Code (QCC) is scanned. A QCC is defined as any
barcode that contains the “:%07” command.
Bits
Controls
0-15
QuickConnect Code special operation
16-30
QuickConnect Code parameter
QuickConnect Code special operation:
0 = No special operation/behavior
1 = Override communication protocol in 1-way mode
2 = Override communication protocol in 2-way mode
3 = Post an event
QuickConnect Code parameter:
For special operations 1 and 2, this parameter is the desired
communication protocol (see register 08).
For special operation 3, this parameter is the event to post (see
register C4).
For example, to force the reader into “raw” communication
protocol mode when scanning a QCC, set this register to 0x10001.
To post the 0x40 JavaScript event after scanning a QCC, set this
register to 0x400003.