Technical information

10/29/2014
Page 60 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
2BD
Allowed Repeated
JavaScript Button
Events
0
0: If the button event is a JavaScript event, the button event will
only be generated once.
1: If the button event is a JavaScript event, the button event will
continue to be generated until the button is released.
2BE
In Stand Event
0
CR2300:
CR2600:
CR3600:
F2
(#242)
This event will be posted when the reader is placed in its stand.
Note: Applies to Bluetooth readers only.
Also see registers 2AB to define the charging base as a ‘Stand’ and
C4 for a list of events
2BF
Out of Stand Event
0
CR2300:
CR2600:
CR3600:
F2
(#242)
This event will be posted when the reader is removed from its
stand.
Note: Applies to Bluetooth readers only.
Also see registers 2AB to define the charging base as a ‘Stand’ and
C4 for a list of events
2C2
In Stand Default Event
FF
(#255)
CR2300:
CR2600:
CR3600:
F0 (#240)
When the reader is placed in the stand and stand detection is
enabled, register C4 will be set to the value in this register.
Note: Applies to Bluetooth readers only.
Also see registers 2AB to define the charging base as a ‘Stand’ and
C4 for a list of events
2C3
Out of Stand Default
Event
FF
(#255)
When the reader is removed from the stand and stand detection is
enabled, register C4 will be set to the value in this register.
Note: Applies to Bluetooth readers only.
Also see registers 2AB to define the charging base as a ‘Stand’ and
C4 for a list of events
2C4
Minimum Motion
Illumination Percent
1
CR6000:
CR3600
DPM:
3
This is the minimum illumination that will be used when in motion
detection mode.
Also see register: 206