Technical information
10/29/2014
Page 59 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
2B0
USB passthrough mode
hysteresis battery
capacity (%)
19
(#25)
When in USB passthrough mode, if the sled battery drops below
the USB passthrough mode minimum battery capacity, the sled
battery must reach this higher capacity before power (and
communication) will be restored to the iPhone.
Note: Supported on CR4405 only.
Also see register: 282, 283, 284, 285, 29C, 29D, 2AF, 2B0, 2C5
2B4
Public Sector Behavior
0
Binary Dip Switch
Bit
Controls
Value
0
Enable public-sector parsing
0: Disabled
1: Enabled
1
Enable JSON formatting
0: Disabled
1: Enabled
2
Reject raw data (non-public-sector-
formatted decodes are considered an
error condition)
0: Disabled
1: Enabled
2B6
Trigger 1 Release Event
0
If non-zero, the specified event is generated when this button is
released.
Also see register: 39
2B7
Trigger 2 Release Event
0
If non-zero, the specified event is generated when this button is
released.
Also see register: 39
2B8
Trigger 3 Release Event
0
If non-zero, the specified event is generated when this button is
released.
Also see register: 39
2B9
Trigger 4 Release Event
0
If non-zero, the specified event is generated when this button is
released.
Also see register: 39
2BA
Trigger 5 Release Event
0
If non-zero, the specified event is generated when this button is
released.
Also see register: 39
2BB
Triggger 6 Release Event
0
If non-zero, the specified event is generated when this button is
released.
Also see register: 39
2BC
Trigger 7 Release Event
0
If non-zero, the specified event is generated when this button is
released.
Also see register: 39