Technical information
10/29/2014
Page 48 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
21B
Reported Board Type
(See
Comment
column)
Valid Range: 1 to 9999
The firmware will report this number as the “hardware type
identifier” field of the reader information string.
CR900FD: 384 (#900)
CR1000: 7
CR1400: 8
CR2600: 9
CR3600: A (#10)
CR2300: 8FC (#2300)
CR4405: C (#12)
CR8000: 6
CR6000: 1770 (#6000)
Note: Supported in firmware version 272+
21C
In Stand Extended
Duplicate Block Time
(ms)
5DC
(#1500)
Valid Range: 0 to 7FFFFFF Milliseconds
Applies to a Reader in a stand. Consecutive duplicate codes (i.e.,
codes that contain the same data) are blocked for this amount of
time (in milliseconds). 0 turns off blocking of duplicate codes.
Note: Supported in firmware version 272+
Also see registers: 159, 2CA
21D
USB Speed
0
0: High Speed
1: Full Speed
Speed at which USB Connection is made.
Note: Supported in firmware version 281+
235
Cradled event
0
CR2300:
CR2600:
CR3600:
CR4405:
E0
(#224)
This event will be triggered when the reader is placed in its cradle.
Note: Supported in firmware version 376+
See register C4 for a list of events