Technical information
10/29/2014
Page 46 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
10B
Enable JavaScript
1
0: Disabled
1: Enabled
When set to 0 installed scripts are disabled. This can be useful from
boot mode for recovering the unit if a non-responsive script is
installed.
10C
Bluetooth Connected
Cache Time (Seconds)
3
Valid Range: 0 to 7FFFFFFF Seconds
The time the last connection status received from the radio
remains valid.
If a request is made during this time since last radio query, the
cached status is returned. Otherwise, the Reader will query the
radio for connection status (which takes up to 1 second).
Note: Only applies to readers using Bluetooth communication
modes.
12D
Hong Kong 2 Of 5
Symbology
0
Binary Dip Switch
Bit
Controls
Value
0
Hong Kong 2 of 5 Decoding
0: Disabled
1: Enabled
12F
Notify Of Packet
Rejection
1
0: Disabled
1: Beep 3 times
0x100xx: post event on No-Read, where the lower 8 bits specify the
event number. For example, 0x10009 to post Event 0x09.
Specify the behavior when a packet is rejected because of incorrect
encryption key, incorrect packet protocol, or CodeXML
®
Modems
locked to a different Reader.
Also see register 39 for a list of events.
137
PDF417 Handle Invalid
Shift
0
0: Disabled
1: Enabled
Allows the decoding of PDF417 barcodes that were improperly
encoded.
Note: This register has no effect on a CR900FD without the proper
2D barcode decoding license.
154
Enable Black And White
Pictures
0
0: Images remain in grey scale.
1: Captured images are converted to black and white.
Converts grey scale images to black and white