Reg
Setting Name
Default
(Hex)
Comment
F0
Allow Code 128 Short
Margin
1
0: Disabled
1: Enabled
F6
Code 39 Short Margin
1
0: disallow short margin Code 39 symbol decoding
1: allow short margin Code 39 symbol decoding
F7
Code 11 Symbology
0
Binary Dip Switch
Bit
Controls
Value
0
Code 11 Decoding with one or
two checksum digits checked
0: Disabled
1: Enabled
2
Strip checksum(s) from the
result string
0: Disabled
1: Enabled
Note: The firmware determines whether one-digit or two-digit
checksum should be checked internally.
F8
Pharmacode Symbology
0
See Section 11.1 - Pharmacode for more details.
Binary Dip Switch
Bit
Controls
Value
0
Pharmacode decoding
0: Disabled
1: Enabled
1
Support color bar
0: Disabled
1: Enabled
3
Reverse instead of Normal
direction
0: Disabled
1: Enabled
Note: The reader decodes a Pharmacode in either horizontal or
vertical orientation by default.
F9
Pharmacode Bar Count
1004
(#4100)
Valid Range: Each 8 bits can be 04 to 10 (#16)
Bit 0 – Bit 7: min bar count, 04 to 10 (#16)
Bit 9 – Bit 15: max bar count, 04 to 10 (#16)
FA
Pharmacode Min Value
F
(#15)
Valid Range: F (#15) to 1FFFE (#131070)
FB
Pharmacode Max Value
1FFFE
(#131070)
Valid Range: F (#15) to 1FFFE (#131070)
FC
Keep reading codes as
long as button is held
down
0
0: Disabled (requires button to be released before next scan occurs)
1: Enabled
Note: When enabled, register 159 should be greater than zero.