Technical information

10/29/2014
Page 41 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
C4
Default Event
FF
(#255)
CR900FD:
CR1400:
CR1000:
CR6000:
F0
(#240)
The default value of FF is the idle event. This means that normally,
no activity is occurring. However, if the value is set to one of those
shown in the list below, then that action will be repeated
continuously, unless interrupted by an external trigger or
command. Any event other than 0 or FF will prevent the reader
from entering power save mode.
This register also causes register 86 to be set to 0, unless motion
detection (F0) is selected as the default event.
Event numbers (same as register 39)
0: No Action
1: Keep Awake
2: Show Target
3: Read In Both Fields (Default)
5: Read In High Density field (FOI 0). See section 8.2
Note: The CR900FD does not have a High Density field (FOI 0)
6: Read In Wide field (FOI 1). See section 8.2
7: Take Picture
8: Read In Most Recently Successful Field
(#13 To #80): Custom events (handled by JavaScript)
(#220): Perform “phone connected” handler
(#221): Perform “phone disconnected” handler
(#222): Perform “cable disconnected” handler
(#223): Perform “reader uncradled” handler
(#224): Perform “reader cradled” handler
(#225): Perform “cabled connected” handler
(#226): Beep
F0(#240): Detect motion
(#241): Toggle Apple KB mode (Bluetooth KB mode only)
(#242): Update behavior based on stand detection
FF(#255): Idle
Also see register: 39