Reg
Setting Name
Default
(Hex)
Comment
A2
Default Event Delay
(ms)
64
(#100)
Valid Range: 0 to 7FFFFFFF Milliseconds
The Reader will pause for this amount of time between each
posting of the default event (used with “continuous read” mode).
Also see register: C4
A7
Beep (Vibrate) Pulse
Separation (ms)
64
(#100)
Valid Range: 0 to 7FFFFFFF Milliseconds
The spacing in milliseconds between beeps when beeping multiple
times.
Note: Readers with a vibration motor are the CR1400, CR2600,
CR3600 and CR6000.
Also see registers: 26, 59, 1F1
AB
AGC Selection for
Picture Taking
0
0: Use decoder AGC (designed for Symbology decoding)
1: Use imager AGC (optimized for pictures)
Also see registers: 36, 43, AC, AD, AE, AF, B1
AC
Wide field (FOI 1)
Picture Window Left
Position
0
Specify left edge of window used with “take picture.” The position
and size are relative to the virtual image (i.e., not the rotated
physical image).
Note: On a Code Reader, overall image is 960 pixels by 1280 pixels.
Upper half is Wide field (FOI 1); lower half is High Density (FOI 0).
The High Density field (FOI 0) does not exist on the CR900FD.
Also see registers: 36, 43, AB, AD, AE, AF, B1
AD
Wide field (FOI 1)
Picture Window Upper
Position
0
Specify upper edge of window used with “take picture.” The
position and size are relative to the virtual image (i.e., not the
rotated physical image).
Note: On a Code Reader, overall image is 960 pixels by 1280 pixels.
Upper half is Wide field (FOI 1); lower half is High Density (FOI 0).
The High Density field (FOI 0) does not exist on the CR900FD.
Also see registers: 36, 43, AB, AC, AE, AF, B1
AE
Wide field (FOI 1)
Picture Window Width
500
(#1280)
Specify width of window used with “take picture.” The position and
size are relative to the virtual image (i.e., not the rotated physical
image).
Note: On a Code Reader, overall image is 960 pixels by 1280 pixels.
Upper half is Wide field (FOI 1); lower half is High Density (FOI 0).
The High Density field (FOI 0) does not exist on the CR900FD.
Also see registers: 36, 43, AB, AC, AD, AF, B1