Technical information

10/29/2014
Page 38 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
9E
Extra Cabled Idle Time
CR2300:
CR2600:
CR3600:
2710
(#10000)
CR4405:
#-500
This is the time added to the idle timeout register 8E if unit is in the
charger. To disable this timer, set the register value to -1 as in the
following example which disables and saves the timer setting with
the ‘C’ command:
C(9E)#-1
Current State: Idle
Next State: Standby
Note: Only applies to readers using Bluetooth communication
modes.
Also see registers: 32, 88, 8E, 9F, 2C, 9E
9F
Standby Mode
Countdown Timer (ms)
FFFFFE0C
(#-500)
CR2300:
CR2600:
CR3600:
927C0
(#600000,
10 min)
CR4405:
EA60
(#60000, 1
min)
Valid Range: 0 to 7FFFFFFF Milliseconds.
This state: Standby (Lowest power usage)
Next state: Sleep ( < 2mA current NON-USB devices ONLY)
Counts down to the end of Standby Mode. (Sleep mode NOT active
in cabled USB devices). To disable this timer, set the register value
to -1 as in the following example which disables and saves the timer
setting with the ‘C’ command:
C(9F)#-1
Standby Mode is the time after the Idle Mode Countdown Timer
has expired and before the Standby Mode Countdown Timer has
expired. There are many user and firmware events that will reset
the timer or send the reader back into a higher-power mode;
therefore it may seem that the timer is longer than the value set.
Note: Only applies to readers using Bluetooth communication
modes.
Also see registers: 32, 88, 8E, 9F, 2C, 9E
A1
Vibrate
1
0: Disabled
1: Enabled (vibration motor will be on at same time as speaker)
Note: if vibrate-only is desired, set speaker volume to 0 using
register 26.
Note: Readers with a vibration motor are the CR1400, CR2600,
CR3600 and CR6000.