Technical information

10/29/2014
Page 35 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
76
Send And Store Mode
0
0: Normal mode (buffered send)
1: Send and log mode
3: Log only mode
Note: Only applies to readers using Bluetooth communication
modes.
Also see register: B4. Reader will not allow the user to set auto-
reconnect on, and store data. If any setting that allows storing data
is turned on, auto-reconnect will be turned off (if it is on).
78
Settings Lock
1
1: Settings unlocked
3: Settings locked (except settings Lock)
85
Tri-Optic Options
0
Binary Dip Switch
Bit
Controls
Value
0
Tri-Optic Decoding, Normal
Quiet Zones
0: Disabled
1: Enabled
1
Allow Short Quiet Zones
0: Disabled
1: Enabled
2
No Quiet Zones Required
0: Disabled
1: Enabled
3
Reverse order of first and
second halves
0: Disabled
1: Enabled
Note: Bit 3 is supported in CD 14.1.2+
86
Motion Detection:
Event
3
Valid Range: Any event as defined in register 39 and re-listed in C4
Motion detection is enabled by setting register C4 to 0xF0.
This register is reset to 0 (disabled) when register C4 is changed
away from 0xF0. When motion is detected, this event is posted.
See register 39 or C4 for list of events.
Also see registers: 204, 20E