Technical information
10/29/2014
Page 23 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
1D
Serial Stop Bits
1
1: Send 1 Stop Bit
2: Send 2 Stop Bits
Also see registers: 1C, 1E, 1F, 22
1E
Serial Data Bits
8
7: 7 Data Bits
8: 8 Data Bits
Also see registers: 1C, 1D, 1F, 22
1F
Serial Flow Control
0
0: Disabled
1: Hardware
Also see registers: 1C, 1D, 1E, 22
22
Serial Parity
0
0: None
1: Odd
2: Even
Also see registers: 1C, 1D, 1E, 1F
26
Beep Volume (percent)
64
(#100)
Valid Range: 0 to 64 (#100) Percent
This is the current percentage of full volume potential.
Also see registers: 59, A7, 1F1
29
PDF417 Symbology
1
0: Disabled
1: Enabled
Note: This register has no effect on a CR900FD without the proper
2D barcode decoding license.
Also see registers: 2A, CF
2A
Micro PDF417
Symbology
0
0: Disabled
1: Enabled
Note: This register has no effect on a CR900FD without the proper
2D barcode decoding license.
Also see registers: 29, CF