Technical information
10/29/2014
Page 22 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
1B
Communications Mode
USB
decode
board: 2
RS232
decode
board: 1
CR2300:
CR2600:
CR3600:
5
CR4405:
C (#12)
1: RS232 Serial
2: USB Keyboard
3: USB IBM POS
4: Bluetooth (SPP)
5: USB Native (HID)
6: USB Virtual COM
7: USB HID POS -Terminal 131
9: Wi-Fi
A (#10): Bluetooth Keyboard
B (#11): iOS® External Accessory mode
C (#12): iOS® Keyboard Mode
D (#13): iOS® USB Pass through Mode
This setting is used in conjunction with registers 08 and 42 to
configure the communication mode between standard “one-way”
and “two-way” modes.
For example, USB “two-way” native:
1b: 5 (USB Native)
08: 2 (packet mode)
42: 1 (expect response)
Note: To switch from USB keyboard mode to Downloader mode
(HID), the following must be completed within 1 second:
first output report with num lock set and caps lock clear
second output report with num lock set and caps lock clear
third output report with caps lock set and num lock clear
fourth output report with caps lock set num lock clear
fifth output report with num lock set and caps lock clear
sixth output report with num lock set and caps lock clear
On the last output report comm protocol is set to raw mode, comm
expect response is false and comm mode is USB Downloader (HID)
mode.
Also see registers: 08, 42
1C
Serial Baud Rate
1C200
(#115200)
All standard baud rates up #115200
2580 (#9600)
4B00 (#19200)
9600 (#38400)
E100 (#57600)
1C200 (#115200)
Also see registers: 1D, 1E, 1F, 22