Technical information

10/29/2014
Page 21 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
19
Data Matrix Symbology
3
Binary Dip Switch
Bit
Controls
Value
0
Data Matrix Decoding
0: Disabled
1: Enabled
1
Inverse Data Matrix Decoding
0: Disabled
1: Enabled
2
Mirror Data Matrix Decoding
0: Disabled
1: Enabled
Note: This register has no effect on a CR900FD without the proper
2D barcode decoding license.
1A
Straight 2 of 5
Symbology
0
0: Disabled
1: Enabled
Straight 2 of 5 (with 2 or 3 start/stop codes) Decoding.
Note: Straight 2 of 5 with 2 start/stop is also called IATA 2 of 5.
Straight 2 of 5 with 3 start/stop is also called Industrial 2 of 5.
CD12.3.0 supports Industrial 2 of 5. CD 13.1.4 supports IATA 2 of 5.