User`s manual

19
MSI/PLESSEY
0) MSI/PLESSEY DECODER
ON Enable reading MSI/PLESSEY labels.
OFF * Disable reading MSI/PLESSEY labels.
1) TWO CHECK DIGITS REQUIRED
ON Two valid CHECK DIGITS are required for each label.
The first check digit is defined by option (2) below.
The second check digit is always MOD 10.
OFF * One valid CHECK DIGIT is required for each label.
The CHECK DIGIT must be MOD 10.
2) FIRST CHECK DIGIT MOD 11
ON The FIRST CHECK DIGIT must be MOD 11.
OFF * The FIRST CHECK DIGIT must be MOD 10.
3) SEND FIRST CHECK DIGIT
ON Transmit the FIRST CHECK DIGIT.
OFF * Do not transmit the FIRST CHECK DIGIT.
4) SEND SECOND CHECK DIGIT
ON Transmit the SECOND CHECK DIGIT.
OFF * Do not transmit the SECOND CHECK DIGIT.
5) ISBN PLESSEY
ON Enable reading of Modified Plessey ISBN bar codes.
Only eleven digit ISBN bar codes will be read.
OFF* Do not read Modified Plessey ISBN bar codes.