Operating instructions

Chapter 11 Operating Instructions
CLV63x Bar Code Scanner
116 © SICK AG · Division Auto Ident · Germany · All rights reserved 8011970/S345/2008-04-16
Appendix
Result status output
Adjustable function of the two independent switching outputs "Result 1" and "Result 2" of
the standard version. Indicates either the status of the reading result (e.g. good read) or the
fulfillment of a definable, event-dependent evaluation condition for the read operation
(such as Match1). The outputs can also be switched off individually or together. The Ether-
net version does not provide any switching outputs on its connectors. However, the function
with two switching inputs can be accessed via connection module CDB620 in combination
with the parameter memory module CMC600.
The "Result" LED is not coupled with one of the result outputs. It only shows status "Good
read" for approx. 100 ms when generating reading results via the data interface.
Saving to the bar code scanner
The application-specific parameter set can be stored in the bar code scanner either tempo-
rarily or permanently. In the case of temporary storage, the parameter set is only contained
in the temporary working memory (RAM) and is lost as soon as the power supply is switched
off. In the case of permanent storage, the parameter set is also transferred to the bar code
scanner’s permanent memory and saved as a current data set after switching off. The de-
fault setting is deposited in a fixed, Read Only Memory (ROM) irrespective of this.
Sending point
Output time of the reading result in relation to the start of the reading pulse and the fulfilled
evaluation conditions.
SMART
620
decoder
Specially developed decoder for reading bar codes with bad or soiled print images.
SOPAS-ET
PC configuration software, to run on Windows 2000
TM
, XP
TM
and Vista
TM
. Used for online com-
munication with the bar code scanner in the dialog (configuration, displaying reading
events, diagnosis) as well as for preparatory offline configuration of stand-alone devices or
the grouping of the same/different SOPAS-ET-compatible SICK devices in a project. The pa-
rameters are exchanged device-specific with the bar code scanner/the devices via upload
and download.
SOPAS-ET help
Online help which supports use of the SOPAS-ET configuration software. The parameter
functions of the bar code scanner are explained in the online help. Runs using an HTML
browser, such as "Internet Explorer
TM
", and can be called up in the SOPAS-ET configuration
software.