Installation Manual
13
E. Programming Options
Default settings in BOLD
OPTION DESCRIPTION
Option Bank 0 - 3 Chirps (Learn Transmitters)
Option Bank One - 4 Chirps (Keyless & Alarm Options)
STATUS INDICATOR
1.Lock with Ignition Doors lock when all doors are closed and ON OFF
ignition is turned on
2.Delayed Door Lock 3 sec. delay locking for theater dimming ON OFF
3.Extended Locks Lock duration is (1) 5 sec. or (2) 0.6 sec. ON(1) OFF(2)
4.Unlock with Ignition Doors unlock when ignition is turned off ON OFF
5.Double Unlock Pulse Unit provides two pulses on each unlock ON OFF
6. Confirmation Chirps (1)Yes (2) No confirmation chirps ON(1) OFF(2)
7.Real Panic Horn Output (1) Random pulsed (2) Steady pulsed output ON(1) OFF(2)
8.Passive Arming Alarm automatically arms 60 sec. ON OFF
after ignition is turned off
Option Bank Two - 5 Chirps (Installer Options)
1.Door Trigger Polarity (1) Positive (2) Negative ON(1) OFF(2)
2.Lite Touch adj ARM raises sensitivity; DISARM lowers sensitivity ON OFF
3.Full Shock adj ARM raises sensitivity; DISARM lowers sensitivity ON OFF
2. System Power-Up and Programming,
cont’d
D. Adjusting the Onboard IT-s
TM
(Interior Theft Sensor)
The IT-s
TM
is factory pre-set at a moderate sensitivity level and has
two adjustment points: Lite-Touch and Full Shock.
To adjust Lite-Touch sensitivity:
1. Enter programming Option Bank 2/Feature 2.
2. Press ARM to increase sensitivity. Press DISARM to decrease
sensitivity.
3. Strike vehicle to test. Chirp will verify impact.
4. Pressing ARM until no siren/horn chirps are heard will disable
Lite-Touch IT-s
TM
.
To adjust Full-Shock sensitivity:
1. Enter programming Option Bank 2/Feature 3.
2. Press ARM to increase sensitivity. Press DISARM to decrease
sensitivity.
3. Strike vehicle to test. Chirp will verify impact.
4. Pressing ARM until no siren/horn chirps are heard will disable
Full-Shock IT-s
TM
.