User manual
58 
GS1 DataBar (GS1 DataBar Truncated) 
GS1  DataBar  Truncated  is  structured  and  encoded  the  same  as  the  standard  GS1  DataBar  format, 
except its height is reduced to a 13 modules minimum; while GS1 DataBar should have a height greater 
than or equal to 33 modules.   
Read: 
Format 
16 Data digits 
Code ID setting: Refer to Code ID setting of UPC-A. 
Insertion group selection: Refer to Insertion group selection of UPC-A. 
Conversion: 
UCC/EAN 128- Refer to Code ID transmission of String transmission, ]Cm will be identified as AIM ID. 
UPC-A or EAN-13- Barcode beginning with a single zero as the first digit has the leading “010” stripped 
and the barcode reported as EAN-13.    Barcode beginning with two or more zeros but not six zeros has 
the leading “0100” stripped and the barcode reported as UPC-A. 
Multiple-scan setting 
Option bar code  Option  Alpha. entry
Single-scan setting 
Disable  00 
Read 
Enable  01* 
* 
00-FF
16
Code ID setting 
00-FF
16
(ASCII) 
<R >* 
* 
00-66   
Insert group selection 
00-66 
00* 
* 
None  00* 
* 
UCC/EAN 128  01 
Conversion 
UPC-A or EAN-13  02 










