User manual
54 
UK/Plessey 
Read: 
Format 
Data digits (variable)  2 check digits (optional)
Check digit verification: The UK/Plessey has one or two optional check digits.    The check digit 1 and 
check digit 2 will be calculated as the sum module 10 or 11 of the data digits. 
Check digit transmission: By setting Enable, check digit will be transmitted. 
Max./Min. code length: Refer to Max./Min. code length of Code 39. 
Code ID setting: Refer to Code ID setting of UPC-A. 
Insertion group selection: Refer to Insertion group selection of UPC-A. 
Multiple-scan setting 
Option bar code  Option  Alpha. entry 
Single-scan setting 
Disable  00* 
* 
Read 
Enable  01 
Disable  00 
Check digit verification 
Enable  01* 
* 
Disable  00* 
* 
Check digit transmission 
Enable  01 
00-99   
Max. code length 
00-99 
00* 
* 
00-99   
Min. code length 
00-99 
01* 
* 
00-FF
16
Code ID setting 
00-FF
16
(ASCII) 
<U>* 
* 
00-66   
Insert group selection 
00-66 
00* 
* 