User manual
54
UK/Plessey
Read:
Format
Data digits (variable) 2 check digits (optional)
Check digit verification: The UK/Plessey has one or two optional check digits. The check digit 1 and
check digit 2 will be calculated as the sum module 10 or 11 of the data digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of Code 39.
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
Multiple-scan setting
Option bar code Option Alpha. entry
Single-scan setting
Disable 00*
*
Read
Enable 01
Disable 00
Check digit verification
Enable 01*
*
Disable 00*
*
Check digit transmission
Enable 01
00-99
Max. code length
00-99
00*
*
00-99
Min. code length
00-99
01*
*
00-FF
16
Code ID setting
00-FF
16
(ASCII)
<U>*
*
00-66
Insert group selection
00-66
00*
*