User manual
44 
Codabar 
Read: 
Format 
Start  Data digits (variable)  Check digit (optional)  End 
Check digit verification: The check digit is made as the sum module 16 of the numerical values of all data 
digits. 
Check digit transmission: By setting Enable, check digit will be transmitted. 
Max./Min. code length: Refer to Max./Min. code length of Code 39. 
Code ID setting: Refer to Code ID setting of UPC-A. 
Insertion group selection: Refer to Insertion group selection of UPC-A. 
Start/End  type:  Codabar  has  four  pairs  of  Start/End  pattern;  you  may  select  one  pair  to  match  your 
application. 
Start/End transmission: Refer to Start/End transmission of Code 39. 
Start/End character equality: By setting Enable, the start and end character of a Codabar barcode must 
be the same. 
Multiple-scan setting 
Option bar code  Option  Alpha. entry
Single-scan setting 
Disable  00 
Read 
Enable  01* 
* 
Disable  00* 
* 
Check digit verification 
Enable  01 
Disable  00* 
* 
Check digit transmission 
Enable  01 
00-99   
Max. code length 
00-99 
00* 
* 
00-99   
Min. code length 
00-99 
00* 
* 
00-FF
16
Code ID setting 
00-FF
16
(ASCII) 
<N>* 
* 