Owner`s manual
Three Flashing Dots with Pump On
104
Pressure or Flow Switch Not Activated: If 3 flashing dots appear below the temperature
display while the pump is operating, turn the pump off. If the 3 flashing dots went away
this indicates that the pressure or flow switch was not activated although there was water
flow. Note: A dirty filter limiting the water flow will also cause this error message to
appear. (Contact Your Local Dealer for Service)
Temperature Sensor
32
If the display shows a constant 32 F or 125 F and this is not the actual temperature or the
displayed temperature greatly differs from the actual spa water temperature, problem with
the water temperature sensor has occurred. Contact Your Local Dealer for Service)
High Temperature
115
If 3 flashing dots appear below the temperature display and the temperature displayed is
115 F or higher, and over temperature condition and a need for service has occurred.
(Contact Your Local Dealer for Service)
NOTE: If you notice the pump coming on for seemingly no reason throughout the day,
the system may be in “Smart Winter Mode”. If you cannot control some functions of the
spa be sure to check to see if the Filtration Indicator is illuminated. The spa may be in
the midst of a filtration cycle. Freeze Protection and Over Temperature Condition will
also limit or disable spa functions.
TROUBLESHOOTING
The following describes situations and possible solutions to common problems you
may encounter as a spa owner.
NOTHING WORKS:
Main Breaker is Off - Set to On.
Sub-Panel Breaker Off - Set to On.
Equipment GFCI Off - Set to On.
Power switch in Off position - Set to On.
Components not plugged in - Plug in components.
Power cord not plugged in - Plug in power cord.
Over or High Temperature Protection On - Refer to “Error Identification”
NO, LOW OR SURGING WATER FLOW
Air Lock in Plumbing System - “Bleed” the system.