Owner`s manual

Programming Filter Cycle Duration: You may choose to filter your spa 60, 120, 180 or
480 minutes per cycle as required to keep the water clean and sanitary. Press and hold
the Light Key. The current duration of the filter cycle will be displayed. Press and hold
the Temperature Set Key in increase or decrease the duration of the filter cycle. The
duration is now set. To start a filter cycle immediately, press and hold the Light Key.
Note: If a Key is not pressed with 5 seconds during programming, the system will revert
back to the monitoring mode. If the Pump and/or light were turned on during the
programming process, turn them off. The system will revert back to display the water
temperature within 5 seconds.
Power Loss: Any interruption of power will cause the unit to reset and revert to the
default programming of 95 F set point temperature and 2, 1-hour filtration cycles.
ADDITIONAL FEATURES
Smart Winter Mode: If the system detects ambient conditions below a present factory
setting, the system will automatically activate the Smart Winter Mode for a period of 24
hours. In this mode, if a pump has not been powered in the last 2 hours, the system will
turn it on for a minute to prevent freezing. The filter Mode light indicator will flash
while the pump is running in this mode. Note: If you notice the pump coming on every 2
hours. This is the most likely cause. This will continue for a 24-hour period. This is
normal and is the systems protection against freezing.
Over Temperature Protection: If the water temperature exceeds 112 F at the Temperature
sensor 3 flashing dots will appear below the temperature display and the heater as well as
all other outputs will shut off. After the water has cooled down power to the spa must be
cycled on then off to reset the system. If the spa water temperature does not seem to
elevated, the error indication may have been caused by poor water flow or electrical line
interference (thunder storms, voltage surges, etc.). Simply reset and monitor the system.
Power-Up Detection: Upon first powering the system or if a power outage occurs, the
display will flash until a key is pressed.
Air Volume Control – (AVC)
The handle valve is used to select jet action between groups of jets, to customize the
therapy action. Adjust to desired therapy action – handle moves only 180 degrees.
OZONE GENERATOR
Ozone is injected into the spa water during the filtration cycle. The ozone generator (if
equipped) operates in conjunction with low speed pump operation and ozone injector.
The ozone is injected into the water to supplement chemical sanitizers, kill bacteria,
15