Owner`s manual
TROUBLESHOOTING
Nothing Operates
Main Breaker is Off - Set to On.
Sub-Panel Breaker Off - Set to On.
Equipment GFCI Off - Set to On.
Power switch in Off position - Set to On
Over or High Temperature Protection On - Refer to Error Identification (High Temperature)
System Fuse Indicator Illuminated
Replace system fuse
If power to electrical pack is OK (check L1 & L2 power using power test switch) - Replace circuit board or pack
No, Low Or Surging Water Flow
Air Lock in Plumbing System - “Bleed” the system.
Restricted Flow - Insure that the water slide valves are open and that suction fittings are not blocked by debris.
Dirty Filter - Clean or replace filters.
Low Water Level - Increase water level to recommended level.
No Filtration Cycle
Water temperature is 4 degrees above set point - Remove spa cover. If the water temperature cools down 1 degree above set point the
pump resumes operation.
No Pump 1
Pump 1 cord not plugged into receptacle - Plug pump 1 into red receptacle.
Pump 1 fuse indicator illuminated - Replace Pump 1 fuse and resume normal operation.
Pump 1 red plug not illuminated - Replace Circuit board.
.
No Pump 2 (if equipped)
Pump 2 cord not plugged into receptacle - Plug pump 2 into pink receptacle.
Aux. fuse indicator illuminated - Replace Aux. fuse and resume normal operation.
Pump 2 pink plug not illuminated - Replace Circuit board.
No Air Blower Operation
Blower cord not plugged into receptacle - Plug Blower into purple receptacle
Aux. fuse indicator illuminated - Replace Aux. fuse.
Blower purple plug not lit - Replace Circuit Board.
Blower purple plug lit - Replace blower or blower cord.
No Therapy Jet Operation
Jets Not Properly Adjusted - Adjust Jets properly.
Thermal Overload Tripping - Check for restricted flow of water.
Over or High Temperature error - Off-On power to reset.
Water Leaks
Spa Overfilled - Adjust water level.
Too Many People in the Spa - Adjust water level.
Drain-Valve Left Open - Close drain valve.
Couplings or Unions Loose - Tighten or contact your local dealer, or manufacturer.
Plumbing / Connections Leaking - Contact manufacturer.
Water in Air Blower Plumbing - Contact manufacturer.
12