If the display shows a constant 32 degree F or 125 degree F and this is not the actual temperature or the
displayed temperature greatly differs from the actual spa water temperature, a problem with the water
temperature sensor has occurred. (Contact your spa dealer or manufacturer).
High Temperature
If 3 flashing dots below the temperature display and the temperature displayed is 115 degrees F or
higher, and over temperature condition has occurred and service is needed. (Contact your spa dealer or
manufacturer).
For Simplicity CS6230 main control panel shown in fig. 7, same error identification is for the CS6200
main control panel.
117117
3232
Manufacturer Of Quality Spas
Jets 1
Aux
Light
Up
Down
TM
Engineered With Visual Illumination
Visual Diagnostic System
Blower
R
R
ERROR IDENTIFICATION (CS6200, CS6230)
Three Flashing Dots with Pump Off
Pressure or Flow Switch Activated: If 3 flashing dots appear below the temperature display while there
is no pump operating, turn on the pump. If the 3 flashing dots stop this indicates that the pressure or
flow switch was activated although there was no water flow. (Contact your spa dealer or manufacturer).
Three Flashing Dots with Pump On
Pressure or Flow Switch Not Activated: If 3 flashing dots appear below the temperature display while
the pump(s) is operating, turn the pump(s) off. If the 3 flashing dots stop this indicates that the pressure
or flow switch was not activated although there was water flow. Note: A dirty filter limiting the water
flow will also cause this error message to appear. (Contact your spa dealer or manufacturer).
Manufacturer Of Quality Spas
Jets 1
Aux
Light
Up
Down
TM
Engineered With Visual Illumination
Visual Diagnostic System
Blower
R
R
104104
104104
ADDITIONAL FEATURES
To prevent overheating of the spa water, the filtration cycle will be suspended any time the temperature reaches 4 degrees F above the
set temperature for 3 hours. If the spa water cools to 1 degree F above the set temperature while the filtration cycle is still active
(filter indicator flashing) the filtration cycle will reactivate. The filtration cycle will be suspended if the user enters the spa and
activates a pump or blower manually. This is to prevent unnecessary operation of the ozonator. The cycle will be suspended for 40
minutes beyond the last manual activation of any accessory. The filter indicator will flash on the display while the filter cycle is
suspended.
Smart Winter Mode: If the system detects ambient conditions below a present factory setting, the system will automatically activate
the Smart Winter Mode for a period of 24 hours. In this mode, if a pump has not been powered in the last 2 hours, the system will turn
it on for one minute to prevent freezing. The filter Mode light indicator will flash while the pump is running in this mode. Note: If
you notice the pump coming on every 2 hour, this is the most likely cause. The Smart Winter Mode will continue for a 24-hour
period. This activity is normal and is the system protection against freezing.
Over Temperature Protection: If the water temperature exceeds 112 degrees F at the Temperature sensor 3 flashing dots will appear
below the temperature display and the heater as well as all other outputs will shut off. After the water has cooled down power to the
spa must be cycled on then off to reset the system. If the spa water temperature does not seem to be elevated, the error indication may
have been caused by poor water flow or electrical line interference (thunderstorms, voltage surges, etc.). Simply reset and monitor the
system.
PROGRAMMING FILTRATION
You may choose to filter the spa 1, 2, or 3 times per day as required to keep the water clean and sanitary. Duration and frequency of a
filtration cycle is user programmable.
FC - Filtration Cycle. To set frequency press and hold Jets 1 Key for 5 seconds. Use the Temperature Keys to set FC frequency (1, 2,
or 3 times a day). To save the data press the Jets 1 Key within 5 seconds after adjustment. If the Jets 1 Key is pressed a second time
within 5 seconds after adjustment the data will be saved and AC will start immediately. If the Key is not pressed the data will be
saved and AC will start 12 hours later. (Default setting is twice per day).
FC duration setting. To set duration press and hold Light Key for 5 seconds. Use the Temperature Keys to set FC duration (60, 120,
180, 480 minutes). To save the data press the Light Key with in 5 seconds after adjustment. If the Light Key is pressed a second time
with in 5 seconds after adjustment the data will be saved, and FC will start immediately. If the Key is not pressed the data will save
and FC will start 12 hours later. (Default setting is 120 minutes). On some spas, default setting can be different.
Power Loss - Any interruption of power will cause the unit to reset and revert to the default programming of 100 degrees F set point
temperature and twice per day, 2 hours filtration cycles.