8. Absolute maximum ratings
Input Voltage (Vin relative to GND): 0V to 36V
SDA, SCL pin input voltage (relative to GND): -0.3V to 5.5V
Input Current: 4.5A (average)
Storage temperature: -55°C to 115°C
Ambient temperature with power applied (no output driven): -40°C to +85°C
ESD: 2000V (human body model)
Absolute maximum ratings must not be exceeded or permanent damage to the LED-Warrior04 may
result.
8.1. Operating Conditions
Input Voltage (Vin relative to GND): 0V to 32V
SDA, SCL pin input voltage (relative to GND): 0V to 5V
Operating temperature: -10°C to +60°C in still air
Maximum output power per channel: 25W
Maximum output current per channel: 1A
8.2 Thermal precautions
When operating at elevated ambient temperature,
vertical mounting in an air volume sufficiently
large to allow convection is recommended to
reduce surface temperature of the regulator.
Additional cooling measures can help to further
reduce the regulator temperature and increase long
term reliability.
No part of the module surface may exceed 95°C
during operation.
8.3 Failure modes
The most common failure mode seen when the
LED-Warrior04 is destroyed due to a departure
from maximum operating conditions is that it goes
into an inert status. Though it is not impossible that
a failure can lead to an internal short circuit.
8.4 Recommended safety measures
Failure current limiting by a fuse dimensioned for
the application or by a power source that is current
limited is recommended.
V0.8.0 June 15th 2015 Draft