User manual
Code Mercenaries
5
LL
LL
EE
EE
DD
DD
--
--
WW
WW
aa
aa
rr
rr
rr
rr
ii
ii
oo
oo
rr
rr
00
00
11
11
8. Absolute maximum ratings
Input Voltage (Vin relative to GND): -0.3V to +30V (40V for 0.5sec)
MOD pin input voltage (realtive to GND): -0.3V to +6V
Input Current: 1.25A
Operating temperature:
LW01-350: -30°C to +85°C in still air
LW01-700: -30°C to +85°C in still air
LW01-1000: -30°C to +65°C in still air
Absolute maximum ratings must not be exceeded or permanent damage to the LED-Warrior01 may
result.
8.1 Thermal precautions
When operating at elevated ambient temperature,
vertical mounting in an air volume sufficiently
large to allow convection is recommended to
reduce surface temperature of the regulator.
Additional cooling measures can help to further
reduce the regulator temperature and increase long
term reliability.
No part of the module surface may exceed 125°C
during operation at any time.
8.2 Electrical Characteristics
Input Voltage (Vin): 7V to 30V
Standby current (MOD grounded): 20μA to 40μA
Output current (tested parameter):
LW01-350: 348mA ±20%
LW01-700: 699mA ±10%
LW01-1000: 1000mA ±10%
8.3 Failure modes
The most common failure mode seen when the
regulator is destroyed due to overtemperature or
overcurrent is a short circuit between Vin and
GND.
Overvoltage typically also leads to a short circuit
between Vin and GND, additionally the LEDs can
be exposed to overvoltage in this case.
8.4 Recommended safety measures
An appropriate fuse or other current limiting
measure in the power supply is required to prevent
fire hazards in case of malfunctions.
Materials with low flash points must be kept away
from the regulator. The surface temperature of
parts of the regulator may reach up to 125°C
surface temperature when used at elevated ambient
temperatures and maximum power.
V1.0.1 September 11th 2008