Specifications

52 Pelco Manual C1920M-D (4/03)
16. If you have a server, each keyboard controls its corresponding monitors. In single mode,
keyboard 1 controls monitor 1, keyboard 2 controls monitor 2, etc. In paired mode,
keyboard 1 controls monitor 1 (main) and monitor 2 (spot), and keyboard 3 controls
monitor 3 (main) and monitor 4 (spot). In paired mode, keyboards 2 and 4 are not used.
17. If you have a server and cannot change between full-screen and multi-screen views
on the main monitor, check the MAIN MONITOR CONTROL setting in the server’s
Monitor menu.
18. Adjust the VCR’s head tracking control until the picture stabilizes if:
a. the picture appears jittery when the multiplexer is in VCR playback mode, or
b. one camera view sequences out of order when the multiplexer is in multi-screen
VCR playback mode.
19. If you have a Genex/KBD4000/Esprit with wiper combination, in order to make the
wiper function when Genex is in Track Main mode, you must do the following:
a. Call the spot monitor.
b. Call the camera.
c. Press the auxiliary ON key.
RESET
To reset the multiplexer:
1. Unplug the power cord.
2. Hold down the VIEW button on the multiplexer’s front panel while plugging the power
cord into an electrical outlet. When the Initialization menu appears, release the VIEW
button. The monitor indicates PLEASE WAIT and begins a 20-second countdown.
When the countdown finishes, this menu disappears, all programming menus are at
their default settings, and the multiplexer is ready for use.
3. Reprogram the multiplexer. Refer to the
Programming
section.