Specifications
Pelco Manual C1920M-D (4/03) 35
Video Termination
Set to 75 OHM when equipment is connected only to the video IN connector.
Set to LOOP HI-Z when equipment is connected to both the video IN and video OUT
(looping) connectors. Equipment connected to the looping connector must be
terminated at 75 ohms.
Alarm Input
Refer to the
System Setup
section for an explanation of normally closed and normally
open operation.
Coaxitron Format
EXTENDED - Use when your system has moveable cameras controlled by 32-bit
Coaxitron receivers, such as Esprit™, Intercept, Spectra, IRD/ERD2000 Series, and
LRD41C21/LRD41C22 Series.
OFF - Use when your system has fixed cameras only.
STANDARD - Use when your system has moveable cameras controlled by 15-bit
Coaxitron receivers, such as the CX9000 Series, the PT7700, and the ED25/27/28/29.
Activity Detection
A camera can be set to respond or not respond to activity. If enabled, select SET
DETECTION MASK to define what part of the camera’s viewing field will be monitored
for activity.
4. To program another camera, press the button for that camera. Repeat steps 2-3.
5. When you finish all the changes you want to make, go to EXIT.
6. Press the +/- button to exit programming mode.
When HELP is highlighted, you can press the +/- button to display a help screen that tells
you which buttons to press to configure specific options.
ACTIVITY MASK SETUP
ACTIVITY DETECTION HIGH SENSITIVITY
SET ALL CLEAR ALL EXIT TEST
LOW SENSITIVITY
MED SENSITIVITY
HIGH SENSITIVITY
BOX
BOX
Figure 26. Activity Detection Mask
Activity detection continually monitors selected camera inputs for activity. When activity is
detected, the multiplexer increases the frequency with which those cameras are shown and
recorded. Activity detection is most effective when only a few cameras are showing activity.
As the number of cameras with activity increases, the slower the frequency at which they
can be shown and recorded. If all 16 cameras show activity, there will be virtually no
increase.