Specifications
DS7400Xi Ver. 3+ Reference Guide Copyright © 2004 Detection Systems, Inc. P/N: 28995K Page 68
11.38 Phone Number Programming: Program Addresses (4028, 4038, 4048)
Notes:
To dial the “*” character, enter *1 (The “*” character is sent as “1” “1” when pulse dialing).
To dial the “#” character, enter *2 (The “#” character is only valid when tone dialing).
To input a three second delay, enter *3.
To wait for the dial tone, enter *4 in the first digit.
To disable a Phone Number, enter *5 in the first digit.
(*1 - *5 are Hex values. They will display as B - F at the keypads.)
Recommendation: The phone line that the control panel is connected to should not have a Call Waiting feature. If it must have call
waiting, program the code to disable call waiting and add a three second delay before the phone number. This will prevent incoming calls
from interrupting a communication. For example: call waiting can be disabled in many areas by dialing *70 before the phone number for
tone dial and 1170 for pulse dial.
11.39 Pager Delay Time: Program Address (3914)
When using the Pager Dialing Format (selected in Addresses 0529 and 0530), you may insert a delay time after the phone number is
dialed and before the reports are sent to the pager system. This delay can be used to allow for greeting and instruction messages in the
pager system. This delay will not affect any other report formats.
1
1.38.3 Phone Number 3 (Remote Programmer) Programming: Program Address (4048
)
1
1
.
3
8
.
1
P
h
o
n
e
N
u
m
b
e
r
1
P
r
o
g
r
a
m
m
i
n
g
:
P
r
o
g
r
a
m
A
d
d
r
e
s
s
(
4
0
2
8
)
11.38.2 Phone Number 2 Programming: Program Address (4038)
1234567891011121314151617181920
1234567891011121314151617181920
1234567891011121314151617181920
Example:
To program Phone Number 1 as 555-1212.
Data Digit 1 = [5], Data Digit 2 = [5], Data Digit 3 = [5], Data Digit 4 = [1], Data Digit 5 = [2], Data Digit 6 = [1], Data Digit 7 = [2]
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [4] [0] [2] [8]
Enter Data Digit 1 = [5], Data Digit 2 = [5], Data Digit 3 = [5], Data Digit 4 = [1], Data Digit 5 = [2], Data Digit 6 = [1], Data Digit 7 = [2]
Enter the pound key: [#]
Program the next Address, Program a different Address, or Exit the Programmer’s Mode.
Data Digit
12
Address 3914
Pager Delay Time
0 to 99 seconds Default = 00 sec.
Note: Cannot be used for UL Listed Fire Ap-
plications.