Specifications
DS7400Xi Ver. 3+ Reference Guide Copyright © 2004 Detection Systems, Inc. P/N: 28995K Page 50
11.21 General Code “Arm Only” Programming: Program Address (0198-0201)
This allows for a user with a General Authority level to Arm and Bypass zones he is not able to Disarm.
See Glossary (section 6.1) for further details.
11.22 Arming Warning Programming: Program Addresses (0202-0205)
Arming Warning programming defines whether the keypad will be audible
during the exit delay and auto arm period. If programmed, the keypad
sounder will activate once every 5 seconds during the exit delay. At 10
seconds and 5 seconds remaining, the keypad sounder will activate 3
times. During auto arming, a pre-arming period will begin 15 minutes be-
fore the system arms automatically. The keypad sounders will pulse five
times every minute. During the last five minutes before arming, these
sounders will be on steady.
Example:
To program a General Authority level to be able to Arm
and Bypass zones he is not able to Disarm in Partition 1
.
Data Digit 1 = [1], Data Digit 2 = [0].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [9] [8] (Data Digit 1)
Enter Data Digit 1: [1]
Enter Data Digit 2: [0]
Enter the pound key: [#]
Program the next Address, Program a different
Address, or Exit the Programmer’s Mode.
0
1
General Code can Arm, Disarm, and Bypass
Select Option DD
General Code can Arm and Bypass
3
General Code can Arm
2
General Code can Arm and Disarm
Data Digit 1 Data Digit 2
Partition 5 Partition 6
P
r
o
g
r
a
m
A
d
d
r
e
s
s
0
2
0
0
Data Digit 1 Data Digit 2
Partition 7 Partition 8
Program Address 020
1
Data Digit 1 Data Digit 2
Partition 1 Partition 2
P
r
o
g
r
a
m
A
d
d
r
e
s
s
0
1
9
8
Data Digit 1 Data Digit 2
Partition 3 Partition 4
Program Address 0199
Example:
To program the keypads in Partition 1 to be audible during exit delay
and the keypads in Partition 2 not to be audible during exit delay.
Data Digit 1 = [4], Data Digit 2 = [0].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [2] [0] [2]
Enter Data Digit 1: [4]
Enter Data Digit 2: [0]
Enter the pound key: [#]
Program the next Address, Program a different Address, or Exit the
Programmer’s Mode.
DD
Partition 1
4
No Keypad Sounder during Exit Delay
Data Digit
12
P
A
0
2
0
2
Keypad Sounder during Exit Delay
0
DDPartition 2
4
No Keypad Sounder during Exit Delay
Keypad Sounder during Exit Delay
0
DDPartition 5
4
No Keypad Sounder during Exit Delay
Data Digit
12
P
A
0
2
0
4
Keypad Sounder during Exit Delay
0
DDPartition 6
4
No Keypad Sounder during Exit Delay
Keypad Sounder during Exit Delay
0
DD
Partition 3
4
No Keypad Sounder during Exit Delay
Data Digit
12
PA 0203
Keypad Sounder during Exit Delay
0
DD
Partition 4
4
No Keypad Sounder during Exit Delay
Keypad Sounder during Exit Delay
0
DD
Partition 7
4
No Keypad Sounder during Exit Delay
Data Digit
12
PA 0205
Keypad Sounder during Exit Delay
0
DD
Partition 8
4
No Keypad Sounder during Exit Delay
Keypad Sounder during Exit Delay
0