Specifications
DS7400Xi Ver. 3+ Reference Guide Copyright © 2004 Detection Systems, Inc. P/N: 28995K Page 46
11.13 Custom Arming Programming: Program Addresses (0183-0184) (Continued)
11.14 Force Arming and Ground Fault Detect Programming: Program Address (0185)
Force Arming programming defines how many zones may be Force Armed using an Arm-
ing sequence followed by the [Bypass] key. With this entry, all violated zones (up the pro-
grammed limit) will automatically be Force Armed (bypassed). Ground Fault Detect pro-
gramming determines whether or not the control will detect a ground fault condition.
See Glossary (section 6.9) for further details.
Force Arming is not allowed
on U.L. Listed systems.
I
MPORTAN
T
0
0 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Bypass Zone Function 9
Bypass Zone Function 10
Bypass Zone Function 11
Bypass Zone Function 12
12
1 2 3 4 5 6 7
Bypass Zone Function 13
Bypass Zone Function 14
Bypass Zone Function 15
Select Options
Data Dig
it
Enter the Data Digit as a:
Select Options
Enter the Data Digit as a:
P
A
0
1
8
4
*0 - *5 are Hex values. They will display as A - F at the keypads.
Example:
To be able to Force Arm up to 5 Zones and
have Ground Fault Off.
Data Digit 1 = [5], Data Digit 2 = [0].
Enter the Programmer’s Mode:
[9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [8] [5]
Enter Data Digit 1: [5]
Enter Data Digit 2: [0]
Enter the pound key: [#]
Program the next Address, Program a different
Address, or Exit the Programmer’s Mode.
0
DD
Do not allow Force Arming
Allow up to 1 zone to be Force Armed
0
1
Allow up to 2 zones to be Force Armed
2
3
Allow up to 3 zones to be Force Armed
Allow up to 4 zones to be Force Armed
Allow up to 5 zones to be Force Armed
4
5
Allow up to 6 zones to be Force Armed
6
7
Allow up to 7 zones to be Force Armed
Allow up to 8 zones to be Force Armed
Allow up to 9 zones to be Force Armed
8
9
12
Select Option
Data Digit
DD
1
Select Option
Ground Fault Detect Off
Ground Fault Detect On