Specifications

DS7400Xi Ver. 3+ Reference Guide Copyright © 2004 Detection Systems, Inc. P/N: 28995K Page 45
11.12 Emergency Key Programming: Program Addresses (0181-0182)
Emergency Key and Panic Key programming disables or activates these
keys (the A, B, and C keys) located on the keypads.
It also determines a silent, pulsed, or steady alarm.
See Glossary (section 6.7) for further details.
11.13 Custom Arming Programming: Program Addresses (0183-0184)
Example:
To program the Fire Key and the Special Emergency Key as both
having a Steady Alarm.
Data Digit 1 = [2], Data Digit 2 = [2].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [8] [1]
Enter Data Digit 1: [2]
Enter Data Digit 2: [2]
Enter the pound key: [#]
Program the next Address, Program a different Address, or Exit the
Programmer’s Mode.
Example:
To program the [4] to Bypass Zone Function 1 only.
Data Digit 1 = [1], Data Digit 2 = [0].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [8] [3]
Enter Data Digit 1: [1]
Enter Data Digit 2: [0]
Enter the pound key: [#]
Program the next Address, Program a different
Address, or Exit the Programmer’s Mode.
0
0
1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Bypass Zone Function 1
Bypass Zone Function 2
Bypass Zone Function 3
Bypass Zone Function 4
12
1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Bypass Zone Function 5
Bypass Zone Function 6
Bypass Zone Function 7
Bypass Zone Function 8
Select Options
Data Digit
Enter the Data Digit as a:
Select Options
Enter the Data Digit as a:
P
A
0
1
8
3
*0 - *5 are Hex values. They will display as A - F at the keypads.
*0 - *5 are Hex values. They will display as A - F at the keypads.
Data Digit
0
Fire Key Disabled
Fire Key = Disabled
Fire Key = Steady Alarm
1
2
Fire Key = Pulsed Alarm 3
Select Option DD
Fire Key
A
May be forced to a different value when in
Commercial Fire Mode. See section 11.15.3.
12
Armed
Status
Pow er
Fire
1 23
456
789
0
*
#
On
No
Entry
Sys te m
Reset
Bypass
Only
Perimeter
Off
®
ABC
0
Special Emergency Key Disabled
Special Emergency Key = Silent Alarm
Special Emergency Key = Steady Alarm
1
2
Special Emergency Key = Pulsed Alarm 3
Select Option DD
Emergency Key
B
0Panic Key Disabled
Panic Key = Silent Alarm
Panic Key = Steady Alarm
1
2
Panic Key = Pulsed Alarm 3
Data Digit
12
Data Digit 2
must be 0
0
0
Select Option DD
Panic Key
C
M
ay be forced to a different value when in Commercial Fire Mode. See section 11.15.3.
PA 0181
PA 0182