11.6 Output Programming: Program Addresses (0146-0148)
Output programming defines the event, partition, and type of alarm (burg
or fire) that will trigger each of the three physical outputs on the control
panel.
See section 3.0 for the location of the physical outputs on the control
panel.
See Glossary (section 6.4) for further details.
Example:
To program the Programmable Output 1 as: following a Burglar Zone
Alarm that is in Partition 1.
PA 0147: Data Digit 1 = [6], Data Digit 2 = [1].
PA 0149: Data Digit 1 = [8], Data Digit 2 = [0].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [4] [7]
Enter Data Digit 1: [6]Enter Data Digit 2: [1]Enter the pound key: [#]
Enter the Program Address: [0] [1] [4] [9]
Enter Data Digit 1: [8]Enter Data Digit 2: [0]Enter the pound key: [#]
Program the next Address, Program a different Address, or Exit the
Programmer’s Mode.
Alarm
Programmable Output 1
Programmable Output 2
0146
0148
6 3
2 3
Output Address Default
0
Latch on ANY Zone Alarm**
ON during Entry Pre-Alert/Exit Warning
ON for 10 sec. after pressing [System Reset]
ON when system is Armed
Ground Start
System Status (ready to arm)
Zone Alarm
Zone Alarm delayed by 20 sec.
Keypad Sounder Output
Access Output (10 sec. pulse)
1
2
3
4
5
6
7
8
9
12
DD
Data Dig
it
** = This includes invisible zones. See glossary for further details.
*** = See section 6.4 for description of this option.
Programmable Output 1 will
be ON for 10 seconds after
pressing [System Reset].
Programmable Output 2 will
be OFF for 10 seconds after
pressing [System Reset].
Select Option
Panic Duress Output***
*1
Burglar Alarm
Fire Alarm
Disabled
Burg and Fire Alarm
DD
0
1
2
3
Options
3
Armed Full
Armed Partial
Disabled
DD
0
1
2
Options
3
Armed Any
3 30147