8.0 Keypads
8.1 The Master Keypad
Your system may include a Master keypad.
A Master keypad is a DS7447/DS7447E keypad programmed to give a user access to all the partitions he has access to, not just the
partition the Master keypad is in. This is different from a Standard keypad in that Standard keypads only give access to the single partition
they are in. Commands entered at the Master keypad will affect all the partitions the user has access to. If this is not desirable, the Master
keypad can be used to control partitions individually; this is called Single Partition Mode. Single Partition Mode allows a user to control
the partitions he has access to on an individual (one by one) basis (see section 8.4 for more information on Single Partition Mode).
8.2 Master Keypad Displays
Master keypad displays will differ slightly from Standard keypads.
The Master keypad display will scroll the Status of each partition, followed by the partition number.
For example, if all partitions are armed, the Master keypad will scroll through the following displays:
Armed Armed Armed Armed Armed Armed Armed Armed
Area 1 Area 2 Area 3 Area 4 Area 5 Area 6 Area 7 Area 8
If only partitions 1, 2, 3, 4, 6, and 8 are armed, the Master keypad will scroll through the following displays:
Armed Armed Armed Armed Ready to Arm Armed Ready to Arm Armed
Area 1 Area 2 Area 3 Area 4 Area 5 Area 6 Area 7 Area 8
Displays for partitions that are Not Ready will display in the same manner.
All partitions are disarmed.
Not ready to arm (if the
Armed Light is on, all
partitions are armed).
The control panel has lost
all power; no AC or battery.
There are no fire alarms.
Armed
(red)
Status
(green)
Power
(green)
Fire
(red)
All partitions are armed, and no alarms have
occurred.
All partitions are ready to arm.
Normal Operation.
The control panel is running on AC power
with no problems.
A fire trouble condition exists.
One or more partitions
are armed, or an alarm
has occurred.
One or more zones are
bypassed.
Control panel problems
exist. See Error Displays.
A fire zone is in alarm.
Light Off Flashing On
8.3 Arming from the Master Keypad
Arming all the
Partitions you
have access to.
Arming from the Master Keypad
Enter your PIN followed by one of the arming sequences.
This will alarm all of your partitions, even if some are already armed.
You must enter Single Partition Mode to arm the necessary partitions one at a time.
Arming only
some of your
Partitions
1. Enter your [PIN], followed by the [#] key twice: [1] [2] [3] [4] [#] [#].
2. The first partition you have access to will be displayed:
"Ready to Arm. Cafeteria."
3. Complete the arming command sequence you wish for this partition: [On].
4. Move to the next partition you have access to by pressing the [#] key twice: [#] [#].
5. The next partition you have access to will be displayed:
"Ready to Arm. Office."
6. Complete the arming command sequence you wish for this partition.
7. After you have completed all the arming command sequences for the partitions
you have access to, exit Single Partition Mode by pressing the [*] key for 2 seconds.