Specifications

DS7400Xi Ver. 3+ Reference Guide Copyright © 2004 Detection Systems, Inc. P/N: 28995K Page 30
7.14.4 Communicator Test
This test is available only if your system transmits alarms and system information to a monitoring service, and has been programmed by
the security installing company to permit communicator tests. A long beep will initially sound to acknowledge the start of the test. If the test
is successful, the sounder will again issue one long beep. If the test fails, the keypad sounder will turn ON continuously. To silence the
sounder, enter your [PIN] followed by the [#] key or press the [*] key. This test can be performed from a Master Ketpad. The account code
for partition #1 will be used.
Communicator
Test
• A long beep will sound.
[PIN] + [#] [8] [2]
Type of Test
Command
Sequence
What will Happen
Requires
addresses
0329, 0496,
0529, and 1521 to
be programmed.
If test fails, the keypad sounder
will sound continuously. To
silence the sounder, press the
[System Reset] key.
What to Do
• A "Test" report is sent to the monitoring
service.
Note:
This test may take several
minutes to complete as the
control will try 10 attempts (not
programmable) before it fails this
test.
7.14.5 Event History Readback
The History Buffer stores the last 400 events in memory, the most recent 64 are stored in non-volatile memory (will be kept even if total
power loss). The DS7447/DS7447E can display all of these events. The DS7445/DS7445i will only display those zones that have
alarmed since the last Event History Readback.
Type of Test Command
Sequence
What will Happen What to Do
Event
History
Readback*
[PIN] + [#] [8] [9]
DS7447/DS7447E: The last event to
take place will be displayed.
DS7445/DS7445i: The zone LEDs
will flash for any zones that have
alarmed since the last Event History
Readback done on a
DS7445/DS7445i keypad in that
partition.
For system fault displays, see Section
7.14.7.
For the DS7447/DS7447E, scroll through
the events by using the [9], [6], and [#]
keys.
To exit from the Event History Mode,
press the [*] key.
* = If this test is performed from a Master keypad, it must be in Single Partition Mode.
DS7447/DS7447E Only: Scrolling through the History Events.
To begin scrolling back through the events, press the [#] key. The [#] key will scroll you back through the history line by line. The [9] key will
scroll you back in reverse chronological order by event. The [6] key will scroll you back up through the events (toward the most recent) by
event.
Each event consists of two or three lines or display screens. The first line/screen will be the event title and user. The second line/screen will
be the date of the event or the change being made. If there is a third line/screen, it will be the date of the change.
To exit the Event History Mode, press the [*] key or wait 20 seconds and the keypad will exit automatically.
When performing this from a Master Keypad, each partition will display its own history.
7.14.6 Remote Program Dial-out and Answer
Remote Program
Dial-out*
The panel will call the remote
programmer.
Type of Function What will Happen
[PIN] + [#] [8] [3]
Command Sequence
The panel will answer a call from
the remote programmer.
Remote Program
Answer
[PIN] + [#] [8] [6]
*= Phone numbers 1 and 3 must
be programmed and an Account
Code must be programmed.