Specifications

DS7400Xi Ver. 3+ Reference Guide Copyright © 2004 Detection Systems, Inc. P/N: 28995K Page 10
4.0 Hardware Layout Example
Armed
Status
Powe r
Fire
1 23
456
789
0
*
#
On
No
Entry
Syste m
Reset
Bypa ss
Only
Perimeter
Off
Perimeter
Supervisory
Bell Sile nced
Trouble
12345678
®
DS7488 Octal
Relay Board
DS7400Xi
+–+–
Power Bus
DS7420i Dual Phone
Line/Bell Supervision
Module
DS7447/DS7447E and
DS7445/DS7445i Keypads
R
ARDIS Interface Module
DS7450, DS7452 & DS7455 Series Contacts,
DS7460 Input Modules, DS7465 Input/Output
Modules, MX540, MX775, MX794, MX835, MX934
,
MX938, and MX950 motion detectors and MX28
0
Smoke Detectors
DS7430
Keypads #11 - #15 must be connected to
the Options Bus. Keypads #1 - #10 must
be connected to the Keypad Bus.
®
Note: Ensure at least 1/4" separation
between battery wires and all
other cabling.
Armed
Status
Power
Fire
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypa ss
Only
Peri mete r
Off
®
Armed
Status
Power
Fire
1 23
456
789
0
*
#
On
No
Entr y
Syste m
Reset
Bypa ss
Only
Perimeter
Off
®
Armed
Status
Power
Fire
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypa ss
Only
Peri mete r
Off
®
Armed
Status
Power
Fire
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypa ss
Only
Peri mete r
Off
®
Armed
Status
Power
Fire
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypa ss
Only
Peri mete r
Off
®
Armed
Status
Powe r
Fire
1 23
456
789
0
*
#
On
No
Entry
Syste m
Reset
Bypa ss
Only
Perimeter
Off
Perimeter
Supervisory
Bell Sile nced
Trouble
12345678
®
Armed
Status
Powe r
Fire
1 23
456
789
0
*
#
On
No
Entry
Syste m
Reset
Bypa ss
Only
Perimeter
Off
Perimeter
Supervisory
Bell Sile nced
Trouble
12345678
®
B
G
Y
–+
Option
Bus
Batter y
Bell Output
Auxiliary
Output
+
++
+
+
G
R
B
1
2
3
4
5
6
7
8
9
10
Y
11 12 13 14 15 16 17 1 819 20 21 22 23 24 25 26 27 28
Battery Battery
RTRT TTRR TRTR
DS7432 8 - Input
Remote Modules
47K
Dry contact inputs
+
+
12345678
POWER BUS
+
+
12345678
POWER BUS
+
+
12345678
POWER BUS
+
+
1234567 8
POWER BUS
123 4
5
2
G1
-
+
BUS
NO
+
1
2
3
C
NC
Up to 15 keypads may be used. Keypads #1 - #10 connect to the Keypad Bus and Keypads #11 - #15
connect to the Option Bus. One keypad must be designated as keypad #1 and connected to the Keypad
Bus. See the DS7447 and DS7445 Installation Instructions for further details.
A DS7420i (Dual Phone Line/Bell Supervision Module) may be connected to the control panel, and
placed within the enclosure. Connect to the Options Bus of the control panel. See the DS7420i Installation
Instructions for further details.
A DS7430 (Multiplex Expansion Module) may be connected to the control panel via the expansion port.
This will allow for the connection of additional zones. See the DS7430 Installation Instructions for further
details.
Up to 15 DS7432s (8 Input Remote Modules) may be connected to the DS7430. Connect to the Power
and Bus terminals of the DS7430. This allows for a means of addressing up to 120 input loops of conventional
contacts to the control panel. See the DS7432 Installation Instructions for further details.
A DS7488 (Octal Relay Module) may be connected to the control panel, and placed within the enclosure.
Connect to the Options Bus of the control panel. This provides an additional 8 Form “C” relay outputs for
the control panel. See the DS7488 Installation Instructions for further details.
A Communications Module may be connected to the control panel via the Options Bus. This allows for connection
to the ARDIS radio network.
Up to 128 zones are available for the connection of Single, Multiple, Input/Output, and Multiplex devices.
A DS7436 (Multiplex Expansion Module) may be connected to the control panel via the expansion port.
This will allow for the connection of additional zones. See the DS7436 Installation Instructions for further
details.
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
TEST WEEKLY
12345678
910111213
14 15 16
Armed
Status
Power
Fire
Perimeter
Supervisory
Bell Silenc ed
Trouble
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
TEST WEEKLY
12345678
910111213
14 15 16
Armed
Status
Power
Fire
Perimeter
Supervisory
Bell Silenc ed
Trouble
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
TEST WEEKLY
12345678
910111213
14 15 16
Armed
Status
Power
Fire
Perimeter
Supervisory
Bell Silenc ed
Trouble