Instruction manual

7400 & 7450 Manual
Programming
Page 31
Auxiliary Mode 6
Auxiliary Input Function: Door Monitor
Auxiliary Output activated by: Forced Entry
Example: the keypad can trigger the aux. relay if the door has been
forced open. If the Siren Setting is enabled the siren will be activated.
The aux. input functions as a door monitor switch and is wired to the
magnetic contact on the door. The aux. relay is to be wired to the alarm
system. If the door is forced open, the keypad will wait for the period of
the forced door relay time to elapse and then, it will activate the aux.
relay. The aux. setting sets the forced door delay period.
Auxiliary Mode 7
Auxiliary Input Function: Door Monitor
Auxiliary Output activated by: Door Ajar (door held open)
Example: the keypad can trigger the aux. relay, if it detects that the
door has been held open (ajar) too long. The aux. input functions as
a door monitor switch and is wired to the magnetic contact switch on
the door. The aux. relay is wired to the alarm system. If the door is
opened, the keypad will wait for the door ajar delay time to elapse, and
if the door doesn’t close prior to the end of the period, the keypad will
activatetheaux.relay.Theaux.settingdenesthedoorajartime.Ifan
external sounder is wired in the system and a door ajar event occurs,
the external sounder will chime every few seconds for 1 minute until the
door is closed.
Auxiliary Mode 8
Auxiliary Input Function: Green LED Control
Auxiliary Output activated by: Valid User Code, Auxiliary Code
Example: the keypad can function as a 2 door controller and also
provide indicator functionality control. The aux. relay is wired to the lock
onthe2nddoor.Theaux.settingdenesthedooropentimeforthe2nd
door. The aux. input is used to control the Door Indicator LED. If the aux.
inputisopened,theDoorIndicatorLEDwillashgreen;iftheinputis
closed,theDoorIndicatorLEDwillashred.