Instruction manual

Programming
7400 & 7450 Manual Page 30
Auxiliary Mode 3
Auxiliary Input Function: Toggles Normal/Secure Mode
Auxiliary Output activated by: Alarms
Example: the aux. output is activated if the keypad’s case is forcibly
opened or removed from the wall. By wiring a switch timer or an alarm
system output to the aux. input, the keypad can automatically switch
fromNormalMode(duringofcehours)toSecureMode(afterofce
hours).
You can’t wire a 2nd door in this mode. You can still have door chime
feature active for the 1st door. Refer to Figure 5 on page 13 for wiring
an external sounder.
Auxiliary Mode 4
Auxiliary Input Function: Toggles Normal/Secure Mode
Auxiliary Output activated by: Direct Shunt (explanation below)
Example: the keypad is capable of bypassing an alarm zone by shunt-
ing the door systems sensor. The aux. output is wired to the door sensor
output. When in use, the aux. output is normally open and the door
sensor functions normally. When a valid code is entered, the aux. relay
shuntsthedoorsensorforthedurationoftheshunttime,asdenedby
the aux. setting. If the door is left open longer than the shun time, an
alarm is triggered. Refer to Figure 6 on page 13 for wiring Dynalock
maglocks.
Auxiliary Mode 5
Auxiliary Input Function: Door Monitor
Auxiliary Output activated by: Shunt (explanation below)
Example: the keypad is capable of shunting an alarm system. The aux.
relay is wired to the alarm system. Without a valid code entered, the
aux. relay will match the condition of the magnetic door switch, if the
door opens, the aux. relay will open. If the door closes, the aux. relay will
close. When a valid code is entered, a count down for maximum shunt
time;asdenedbytheaux.setting;begins.Ifthedoorisnotclosed
before the maximum shunt time, the alarm will be triggered.