Instruction manual
7400 & 7450 Manual
Programming
Page 29
4.8.2 Detailed Reference Guide
The following are brief descriptions of each Auxiliary Mode. To imple-
ment the features of each mode, refer to Setting the Auxiliary Mode,
paragraph 4.8.1.
Auxiliary Mode 0
Auxiliary Input Function: Activates the Aux. Output
Auxiliary Output activated by: Valid User or Aux. Code, Aux. Input
Example: the keypad can function as a 2 door controller. The aux. relay
istobewiredtothelockonthe2nddoor.TheAux.Settingdenesthe
door open time for the 2nd door. The aux. input (white wire) is to be
wired to the REX button for the 2nd door. Door Monitor Input is not en-
abled for the 2nd door in this mode. Refer to Figure’s 3 & 4 on pages
11 -12 for wiring the outputs.
Auxiliary Mode 1
Auxiliary Input Function: Toggles Normal/Secure Mode
Auxiliary Output activated by: Valid User or Aux. Code
Example: the keypad can function as a 2 door controller. The aux. relay
is to be wired to the lock on the 2nd door. REX feature for the 2nd door
is not enabledinthismode.TheAux.Settingdenestheopentimefor
the 2nd door. The aux. input can switch the mode of operation between
Normal & Secure Mode. By wiring a switch timer or an alarm system
output to the aux. input, the keypad can automatically switch from Nor-
malMode(duringofcehours)toSecureMode(afterofcehours).
Auxiliary Mode 2
Auxiliary Input Function: Toggles Normal/Secure Mode
Auxiliary Output activated by: Star Button (*)
Example: aux. relay can function as a time switch, activated by depress-
ing the star (*) button. The Aux. Setting establishes how long the aux.
relay is activated. By wiring a switch timer or an alarm system output to
the aux. input, the keypad can automatically switch from Normal Mode
(duringofcehours)toSecureMode(afterofcehours).