Instruction manual

7400 & 7450 Manual
Programming
Page 29
4.8.2 Detailed Reference Guide
The following are brief descriptions of each Auxiliary Mode. To imple-
ment the features of each mode, refer to Setting the Auxiliary Mode,
paragraph 4.8.1.
Auxiliary Mode 0
Auxiliary Input Function: Activates the Aux. Output
Auxiliary Output activated by: Valid User or Aux. Code, Aux. Input
Example: the keypad can function as a 2 door controller. The aux. relay
istobewiredtothelockonthe2nddoor.TheAux.Settingdenesthe
door open time for the 2nd door. The aux. input (white wire) is to be
wired to the REX button for the 2nd door. Door Monitor Input is not en-
abled for the 2nd door in this mode. Refer to Figure’s 3 & 4 on pages
11 -12 for wiring the outputs.
Auxiliary Mode 1
Auxiliary Input Function: Toggles Normal/Secure Mode
Auxiliary Output activated by: Valid User or Aux. Code
Example: the keypad can function as a 2 door controller. The aux. relay
is to be wired to the lock on the 2nd door. REX feature for the 2nd door
is not enabledinthismode.TheAux.Settingdenestheopentimefor
the 2nd door. The aux. input can switch the mode of operation between
Normal & Secure Mode. By wiring a switch timer or an alarm system
output to the aux. input, the keypad can automatically switch from Nor-
malMode(duringofcehours)toSecureMode(afterofcehours).
Auxiliary Mode 2
Auxiliary Input Function: Toggles Normal/Secure Mode
Auxiliary Output activated by: Star Button (*)
Example: aux. relay can function as a time switch, activated by depress-
ing the star (*) button. The Aux. Setting establishes how long the aux.
relay is activated. By wiring a switch timer or an alarm system output to
the aux. input, the keypad can automatically switch from Normal Mode
(duringofcehours)toSecureMode(afterofcehours).