Technical data

Oil-pressure system Checking of the pressure, oil-leaks,
Hoses, hose protection devices inspection of hoses
Implements for lifting Safety check, wear and any deformation, actions
Hooks, chains, cables, slings
Implements Oil-leaks, wear and any deformation,
Wallboard forks, buckets, rotators actions, inspection of hoses
Seat, third control station Access inspection,
Frame, fixing screws wear and any deformation, strains
Tele(radio)remote control Test
22.8 Complete overhaul of the crane is required
when 10.000 working hours or 10 years' life
are reached - i.e.:
When one of the limits indicated hereunder is reached:
10.000 working hours, (i.e.: 10 years, 50 weeks a year, 20 hours a week, or 5 years, 50
weeks a year, 40 hours a week)
or
10 years' life of the crane,
a complete overhaul with in-depth structural inspection of the crane must be carried out by
the Manufacturer or by an authorised service centre.
22.9
Instructions for the dismantlement and the demolition
of a FASSI crane
INSTRUCTIONS FOR THE DISMANTLEMENT AND THE DEMOLITION OF A FASSI
CRANE
In case of demolition it is necessary to dismantle the whole machine and separate the diffe-
rent types of materials according to the respective waste disposals requirements.
The materials involved are the following:
- Ferrous materials: fabrications and mechanical components.
- Plastic materials: gaskets, belts, covers.
- Electric materials: windings, controls, electrovalves and similar.
- Oils and lubricants: hydraulic oil, lubricants for reducers, lubricating greases.
- For the truck follow the indications of the manufacturer
- Different material: Mercury (level sensor)
Take extreme care when slinging the components to be disassembled especially with
respect to their weight.
Completely release the residual pressure in the hydraulic circuits and then fully drain
the oil present in the circuits before starting the dismantlement of the relevant compo-
nents. Be careful not to let the oil drop on the ground, therefore collect it in special con-
tainers, since exhausted oil must be eliminated in compliance with the waste disposal
rules in force.
Disable all the electric power supplies (batteries etc.) before dismantling the compo-
nents of the electric circuits.
22.8
MAINTENANCE
INSTRUCTIONS
GRU FASSI