Instruction manual

49
VF Menu List
Chapter 4 Menu Configuration and Detailed Settings
4-2-5 File Menu
<Sync>
Sync signal
settings
Genlock
Input Signal HD-Y HD-Y, HD-SDI Selects the input connector for the
external sync signal. The genlock signal
must be reapplied after modifying this
setting.
HD-Y: HD 3-level sync
HD-SDI: HD-SDI input
Status -- Locked, Not Locked,
No Signal
Display only. Locked: Synchronized
successfully.
Not Locked: Not synchronized.
No Signal: There is no input signal.
<Battery Alarm>
Supply voltage
settings
DC IN (24V) Type Type1 Type1, Type2 Selects the 24 V system supply settings.
Near End 22.2 V 20.5 V to 30.0 V Sets the power supply voltage drop
warning level for the 24 V supply.
End 21.6 V 20.0 V to 24.0 V Sets the power supply exhausted
warning level for the 24 V supply.
DC IN (12V) Type Type1 Type1, Type2 Selects the 12 V system supply settings.
Near End 11.1 V 11.0 V to 17.0 V Sets the power supply voltage drop
warning level for the 12 V supply.
End 10.8 V 10.5 V to 14.0 V Sets the power supply exhausted
warning level for the 12 V supply.
Page Configuration
item
Default Settings Remarks
Page Configuration
item
Default Settings Remarks
<Gamma File>
Gamma file
settings
1 Sets imported user gamma file created
using CVP File Editor.
A preset value of 709(800%) gamma is
stored in configuration item 1 as the
default gamma value. A user gamma file
can be imported, overwriting the preset
value. This value is selected when
Gamma File Preset is executed on the
<File Preset> page.
Importing a gamma file stores all gamma
data within the camera and is user-
selectable.
Name 709(800%) (Up to 12 characters), --
Comment Preset entry
2
Name -- (Up to 12 characters), --
Comment --
3
Name -- (Up to 12 characters), --
Comment --
4
Name -- (Up to 12 characters), --
Comment --
5
Name -- (Up to 12 characters), --
Comment --
Import -- Execute by Enter. Imports gamma file created using CVP
File Editor (up to five) from USB flash
memory or SD memory card.