Installation manual

I/O Control Parameters
114 S1A53838 09/2011
F100 [Freq. 1 reached]
Relay Output – Frequency Level 1 Attained
0.0 to [Max frequency] (FH) Hz 0.0 Hz
The frequency set by parameter F100 is the threshold level for relay output functions 4 and 5 (see page 98).
F101 [Freq. 2 reached]
Relay Output – Frequency Level 2 Attained
0.0 to [Max frequency] (FH) Hz 0.0 Hz
The frequency set by parameter F101 +/- the [Freq.2 bandw.] (F102) detection band is the threshold level for relay output
functions 8 and 9 and the hysteresis for relay output functions 66 and 67 (see page 103
).
F102 [Freq.2 bandw.]
Frequency Attained Detection Band 0.0 to [Max frequency] (FH) Hz 2.5 Hz
Parameter F102 determines the bandwidth around the [Freq.2 reached] (F101) frequency (see diagram above) and the
commanded frequency (see diagram below) driving relay output functions 6 through 9 (see page 98
).