I/O Control Parameters
100 S1A53838 09/2011
26
[Manu reset flt.]
Non-autoresettable detected fault
OFF: None of the detected fault conditions listed below exist
ON: One (or more) of the following detected fault conditions exists and has
stopped the drive:
• E – external detected fault
• E-18 – VIA analog input signal detected fault
• E-19 – main control board CPU communication
• E-20 – excessive torque boost
• E-21 – main control board CPU detected fault 2
• EEP1 – main control board EEPROM detected fault 1
• EEP2 – main control board EEPROM detected fault 2
• EEP3 – main control board EEPROM detected fault 3
• EF2 – ground detected fault
• EPH0 – output phase detected fault detection
• EPH1 – input phase detected fault detection
• Err1 – speed reference
• Err2 – main control board RAM
• Err3 – main control board ROM
• Err4 – main control board CPU detected fault 1
• Err5 – serial communication control
• Err7 – motor current sensor
• Err8 – serial communication network
• Err9 – graphic display option communication interruption
• Etn1 – auto-tuning
• EtYP – drive ratings
• OCA – short-circuit detected in drive output inverter stage
during motor startup
• OCL – short-circuit detected in motor or output wiring during
motor startup
• OH2 - external overheating
• Ot – overtorque
• Uc – underload
• UP1 - Undervoltage
27
[Inv manu reset flt.]
Inversion of Manu reset flt. function
OFF: One (or more) of the following fault conditions exists and has stopped
the drive:
• E – external detected fault
• E-18 – VIA analog input signal
• E-19 – main control board CPU communication
• E-20 – excessive torque boost
• E-21 – main control board CPU detected fault 2
• EEP1 – main control board EEPROM detected fault 1
• EEP2 – main control board EEPROM detected fault 2
• EEP3 – main control board EEPROM detected fault 3
• EF2 – ground fault
• EPH0 – output phase loss detection
• EPH1 – input phase loss detection
• Err1 – speed reference
• Err2 – main control board RAM
• Err3 – main control board ROM
• Err4 – main control board CPU detected fault 1
• Err5 – serial communication control
• Err7 – motor current sensor
• Err8 – serial communication network
• Err9 – graphic display option communication interruption
• Etn1 – auto-tuning
• EtYP – drive ratings
• OCA – short-circuit detected in drive output inverter stage
during motor startup
• OCL – short-circuit detected in motor or output wiring during
motor startup
• OH2 - external overheating
• Ot – overtorque
• Uc – underload
• UP1 - Undervoltage
ON: None of the detected fault conditions listed above exist
Function No. / Description Action