Setup guide

Dedicated Micros ©2007
53
BX2
Zone on Exit Route
This feature is similar to the zone on entry option, but works in the reverse, this allocates an exit route from
the keyswitch to the exit allowing an operator to enable the alarm system for the premises and allow them to
pass through the specied alarm areas without triggering the alarm, in compliance with BS8418, the British
Standard for remote monitoring stations. Diversion from the exit route will result in an alarm being triggered
immediately. This feature is only available when Advanced Alarms are enabled.
Entry Initiator
This is part of the Advanced Alarm Features and when activated will trigger the entry timer. This is the count
down timer that will automatically start when the entry initiator is triggered (e.g. front door) and works in
conjunction with the entry route to ensure the alarm system is not activated by other alarm triggers on the
entry route for this set time.
Exit Terminator
Once the keyswitch is switched on the alarm system will wait for the exit timer to expire to ensure everyone has
exited the building via the exit routes. This timer can be terminated earlier by triggering an exit terminator, e.g.
closing the front door.
Text Only Alarm
This option is not presently supported.
Change Record Rate
Create Database Entry
Connect on Alarm
Archive Alarms
Protect Alarm Images
Both
Enabled
Enabled
Enabled
Enabled
Both, Standard, Variable, None
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Zone
0
1 Actions
Change Record Rate
This allows the record rate to be switched to the alarm rate when the zone is active.
The options available are:
Standard - switches cameras enabled for standard recording to the alarm record rate.
Prole - switches cameras enabled for variable recording to the alarm record rate.
Both - applies to both the variable and standard recording of the selected camera.
Note: When Both is selected the record rates set in the standard and variable record menus will be
added, i.e. if standard is set to 6PPS for 6 cameras (1PPS per camera) and the prole is set to 3PPS,
then that camera will record at 4PPS.
Create Database Entry
An alarm entry will be added to the event database. The zone title will be used as part of the entry information.
Connect on Alarm
The unit will automatically connect to the remote alarm monitoring station. This features is useful in
applications where remote monitoring of multiple sites is required.
Note: The remote reporting settings must be congured and the viewing application must be enabled
to receive remote alarm video, for more details refer to the Networking Guide.