Setup guide

Dedicated Micros ©2007
52
BX2
Zone NOT Input
The unit will only issue the alarm actions if the trigger is received on the zone alarm input and not on the
Zone NOT input. The allocated alarm trigger can be any of these options; VMD, Presets, System, Keywords, No
Contact and General.
Notes on Zone Alarm Input, OR, AND, NOT Inputs
The following example shows how the unit uses the OR, AND and NOT settings when all three parameters are
congured:
Example
With the functions set to the following alarm inputs:
Base Input (Alarm Input) = Aux contact 1
OR input = Aux contact 2
AND input = Aux contact 3
NOT input = Aux contact 4
Result = [(Alarm1 OR Alarm 2) AND Alarm 3] NOT Alarm 4
The example translates into; an alarm must be received on input 1 AND input 3 but NOT on input 4 OR an alarm
must be received on input 2 AND input 3 but NOT on input 4.
Be aware if an alarm is received on input 4 under the above circumstances the event will not be triggered.
Zone Actions
This identies the actions that will be allocated to the zone being congured.
Note: The actions are spread over three pages.
Zone on entry route
Zone on exit route
Entry initiator
Exit initiator
Text only Alarm
Enabled
Disabled
Disabled
Disabled
Disabled
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Zone
0
1 Actions
Page
This will scroll through all the available actions, there are three pages of actions. Use the or buttons to
scroll through the pages.
Zone on Entry Route
This is part of the Advanced Alarm Features and will create deferred alarms while the entry time is active in
compliance with BS8418, the British Standard for remote monitoring stations.
There will be specic alarm areas associated with the entry route, if someone enters the specied alarm areas
during the entry count down process the alarm will not be triggered allowing the operator to reach the
keyswitch to switch the system into an operating mode where the deferred alarms are disabled. Diverting from
the entry route during the count down will result in the alarm being triggered immediately.