Setup guide

Dedicated Micros ©2007
49
BX2
Alarm Entry Timer
The alarm entry timer is the time interval between an entry initiator being activated and alarms being triggered.
This timer will allow a key holder to enter the premises and have sufcient time to disable the alarm system
without triggering an alarm. This is set in seconds.
Alarm Exit Timer
The exit timer is the time allocated to allow the key holder time to leave the premises once the keyswitch has
been activated, if the alarm system detects a presence after the exit timer elapses then alarms will be triggered.
Forced Day, Night, Weekend
The unit supports three operating modes which by default are set as Day, Night and Weekend. Each operating
mode can be congured with different recording and alarm settings. This option enables the ‘Force’ buttons on
the unit web interface to be active allowing a remote user (with the correct username and password) to access
the unit via the web pages and force the unit into another operating mode for a set time period
Tip: For more information on the web interface refer to the unit Networking Guide.
Alarm Zone Cong
An alarm zone logically groups alarms and initiates actions when an alarm is activated. Each Alarm Zone can be
individually congured within this menu.
Zone
Zone 01 Activation
Zone 01 settings
Zone 01 actions
Primary camera Zone 01
Select zone 01 camera
030 sec
030 sec
Disabled
Disabled
Disabled
000 - 999 sec
Selected cameras, All cameras
A
larm Zone
C
onfi
g
uratio
n
Zone
There are 32 zones that can be individually congured and allocated actions. Use the or buttons to scroll
through the zones.
Pre-Congured Zones
There are a number of pre-congured zones that have the following functions, however these can be re-
congured if required.
Zone 1 to 16 - Camera Alarms.
Zone 30 - Disk Low.
Zone 31 - Disk Full.
Zone 32 - Panic Alarm.
Zone Activation
Each zone can be scheduled to be always enabled (24Hr) or individually activated during the day, night and at
weekends.