Setup guide

Dedicated Micros ©2007
47
BX2
Camera Fail Buzzer
The unit has a built in buzzer which can be enabled to be automatically triggered if any of the video inputs no
longer detects the 1Volt pk-pk signal.
This buzzer can be enabled or disabled within this menu, by default the option is disabled.
Relays
It is possible to congure any of the on-board relays or the additional modules to automatically trigger under
specic conditions. The ‘Schedule notication’, ‘Primary signal failure’ and ‘Weekend notication’ relays only
become available when Advanced Alarms are enabled.
Global alarm
Global VMD
Global camera fail
Schedule notification
Primary signal failure
Weekend notification
Relay test
Aux
Aux
Aux
Aux
Aux
Aux
Edit
Relay 1
Relay 2
Relay 3
Relay 4
Relay 5
Relay 6
Aux, Module 1, Module 2, None
Aux, Module 1, Module 2, None
Aux, Module 1, Module 2, None
Aux, Module 1, Module 2, None
Aux, Module 1, Module 2, None
Aux, Module 1, Module 2, None
Relay
S
etup
Global alarm
It is possible to congure any of the AUX alarm contacts or the additional relay modules to be automatically
triggered when a global alarm is identied on the system.
Global VMD
It is possible to congure any of the AUX alarm contacts or the additional relay modules to be automatically
triggered when the system is notied of global VMD.
Global camera fail
The unit can identify when any of the camera input signals goes below the required 1 Volt peak-to-peak. It
is possible to congure any of the AUX alarm contacts or the additional relay modules to be automatically
triggered when the system identies camera fail.
Schedule notication
The BX2 can identify a switch between operating modes (Day, Night, and Weekend). The schedule notication
relay is closed when the unit is switched out of Day operation mode. Any of the AUX relays or the additional
relay modules can be selected.
Primary Signal Failure
The BX2 can be congured to transmit alarm notication to a remote monitoring station. This notication
normally will go via the primary route as congured. If for any reason this fails it is possible to congure the unit
to automatically trigger this relay to give notication of this failure. Any of the AUX relays or the additional relay
modules can be selected.