Setup guide
Dedicated Micros ©2007
37
BX2
Event Prole
Select the prole recording that is to be applied when the unit switches to event recording mode, again the
options available are:
MPEG01 to MPEG12
JPEG01 to JPEG12
When this option is highlighted additional information will displayed on the screen and it is also possible to
access the edit prole screen by pressing the PLAY button, see below for more information.
Pre-trigger rate
This determines the rate the images will be continuously recorded into the pre-alarm memory and are available
for enhanced pre-alarm recording. Select a record rate in PPS (or ms) to be recorded on the camera being
congured.
Pre-trigger time
It is possible to specify the amount of pre-alarm recording that will be captured and added to the alarm
recording to be stored when an alarm is triggered
Prole Description
When a prole is highlighted, its associated description will be displayed.
Prole Parameters
The resolution, PPS and quality setting of the highlighted prole will be displayed.
Editing Recording Proles
Each of the selectable proles can be edited to suit the requirements of the particular application. The standard
proles give a broad range that will suit most applications. To edit a Recording prole, select the prole name
onscreen and press the play button.
JPEG Prole Parameters
Units
The Units option can be set to pictures per second or millisecond.
Prole
This identies the prole that is being congured and can not be selected.
Description
It is possible to allocate a description to each of the proles to allow the Operator to easily identify the selected
prole, use information that is relevant to the settings.
Resolution
The resolution can be select from High, Medium or Low. The corresponding resolution settings can be changed
by selecting the Edit option which will display the JPEG Image sizes screen.
Record rate
This identies the record rate for the selected prole and can be from 00 PPS to 25PPS (PAL) or 30PPS (NTSC)
(40ms PAL or 33ms NTSC). For record rates of less than 1PPS use the milliseconds option which allows settings
of 1000ms to 99999ms. Selecting 00PPS will create a dummy prole that will not record. Use this dummy prole
as a Normal Prole for event recording only.