Setup guide

Dedicated Micros ©2007
34
BX2
Image Size
The unit supports both JPEG and MPEG-4 compression for high quality recording and image display. Images
recorded using the standard recording settings are stored in JPEG format. The settings applied to these images
are congurable.
The image size has two congurable parameters, File Size and Image Resolution.
The le size setting can be congured between 5 to 45 KB. This determines the size of the images that will be
stored on the hard drive. A larger le size allows more detail to be included in the recorded video and provides
higher picture quality, however this also means that the hard disk will be lled faster and images will be
overwritten sooner.
The image resolution setting has been included to allow the most appropriate image resolution to be
congured in line with the selected le size. The image resolution is the number of pixels captured in each
image. To Edit the JPEG image resolution highlight Edit to display the JPEG Image size screen.
Note: When the High, Medium or Low options are highlighted the screen will display information on
where the JPEG image alias is used, i.e. JPEG proles 1 to 12.
Standard Recording
The standard recording resolution can be selected from the high, medium or low options. When selected this
will be reected on the Standard Record Schedule screen.
T
ypical Settin
g
s
Image Quality
Low
Med
High
File Size (KB)
14KB
18KB
25KB
Alias
This allows the alias High, Medium and Low settings to be congured in line with the selected recording
resolutions, these are also used for viewing. When the alias is highlighted the screen will display which of the
JPEG proles the alias is used in and therefore will affect.
Resolution
This identies the resolution for the alias being congured, the options are: 176x128, 352x256, 704x256 or
704x512.
Size
This is the image size for the alias being congured and can be set from 5KB to 45KB.
Tip:
The resolution and size settings should be tested to ensure the most appropriate recordings are
produced which t the customer and storage requirements for the system.