Setup guide

Dedicated Micros ©2007
31
BX2
Keyswitch
The input which activates the keyswitch can be congured for one of the following options:
None - There is no keyswitch operation enabled.
Direct - The direct input on the rear panel has been allocated as the keyswitch trigger.
Aux - The Aux input on the rear panel has been allocated as the keyswitch trigger, select a contact.
Module 01 - Module 16 - select any input on any module to be the keyswitch trigger.
The keyswitch is used to change the unit from one time mode (Day, Night, Weekend) to another when
the input programmed in the settings is activated. If the unit is in Day mode operation, when the input is
received the unit will switch to Night mode. If it is in Night mode the unit will still switch but it will remain
in Night mode. If the unit is in Weekend mode again the unit will switch but remain Weekend mode.
If the keyswitch is switched off. the unit is congured for;
Day mode the unit will stay in day mode, and apply day settings.
Night mode the unit will switch to day mode and apply the day mode settings.
Weekend mode the unit will switch to day mode and apply the day mode settings.
Note: If the Installer has manually congured an individual schedule mode on an alarm zone different to
the rest of the zones or on a camera different to the rest of the cameras (ignoring 24Hr zones), the
option will switch to a read-only eld and display Custom.
Holidays
The holiday prole option allows a user to identify alternative schedule settings that will be actioned on specic
dates; this will ensure the system continues to operate during periods when operators are not present or times
where the standard schedule settings are not appropriate, e.g. bank holiday weekends.
Current list
New date
Profile 1
Profile 2
Profile 3
Profile 10
01/02/2006
01/02/2006
Timed
Timed
Timed
Timed
Profile 1
Profile 2
Day 09:00
Day 09:00
Day 09:00
Day 09:00
Delete
Add
Night 18:00
Night 18:00
Night 18:00
Night 18:00
24Hr Day, 24 Hr Night
24Hr Day, 24 Hr Night
24Hr Day, 24 Hr Night
24Hr Day, 24 Hr Night
24Hr Day, 24 Hr Night
Holiday
s
Prole
There are ten editable proles that can be individually congured for activate period and time settings.
Active Period
The options available are:
Timed (default) The unit will use the Day settings for the period selected and will
switch to the Night settings at the specied time.
24 Hr Day The prole will only use the Day settings for the selected date.
24 Hr Night The prole will only use the Night settings for the selected date.